Konica Minolta Spectrophotometer Portable-CM-2600d_2500d


Specifications

Principal Specifications CM-2600d

Model

CM-2600d

CM-2500d

Illumination / Viewing system

d:8° (diffuse illumination, 8-degree viewing ), equipped with simultaneous measurement of SCI (di:8° specular component included) / SCE (de:8° specular component excluded) Conforms to CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7 and JIS Z8722 Condition C standard.

Sphere Size

Ø 52 mm

Light-receiving element

Silicon photodiode array (dual 40 elements)

Spectral separation device

Diffraction grating

Wavelength range

360 nm to 740 nm

Wavelength pitch

10 nm

Half bandwidth

Approx. 10 nm

Reflectance range

0 to 175%, resolution: 0.01%

Light source

3 pulsed xenon lamps

2 pulsed xenon lamps

Measurement time

Approx. 1.5 seconds (approx. 2 seconds for fluorescent measurement)

Approx. 1.5 seconds

Minim um interval between measurements

3 seconds for SCI/SCE (4 seconds for fluorescent measurement)

3 seconds for SCI/SCE

Battery perfomance

Alkaline manganese:approx. 1000 measurements

Measurement/illumination area

MAV : Ø 8 mm / Ø 11 mm
SAV : Ø 3mm / Ø 6 mm (Selectable between MAV and SAV)

MAV : Ø 8 mm / Ø 11 mm

Repeatability

Spectral Reflectance:Standard deviation within 0.1% (360 to 380 nm within 0.2%)
Colorimetric Value : Standard deviation within ΔE*ab 0.04 (Measurement conditions:White calibration plate measured 30 times at 10-second intervals after white calibration was performed)

Inter instrument agreement

withinΔE*ab 0.2 (MAV/SCI) Average for 12BCRA Series II color tiles compared to values measured with master body.

UV adjustment

Instantaneous numerical adjustment (no mechanical adjustment required) With UV400nm cut filter

No UV adjustment

Measurement mode

Single measurement/automatic averaging of multiple measurements(auto mode: 3, 5, 8 times/manual mode)

Interface

RS-232C standard

Observer condition

CIE: 2° and 10° standard observer

Illuminant condition

CIE: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources)

Display data

Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result

Color space / colorimetric data

L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density statusA /T, WI/Tint (CIE/Ganz), CIE00

Data memory

1700 sets of data (as SCI/SCE 1 data) * 700 sets of data in the "defined in COND." mode.
* Total of the sample data for the COND and TASK modes and color diference target data

Tolerance judgment

Tolerance for color difference (both box and eliptical tolerances can be set)

Power source

4 AA-size battery or AC adapter AC-A305

Dimensions (W × H × D)

69 × 96 × 193 mm

Weight

Approx. 670 g (without batteries)

Operating temperature / humidity range (*1)

5 - 40°C, relative humidity 80% or less (at 35°C) with no condensation

Storage temperature/humidity range

0 - 45°C, relative humidity 80% or (at 35°C) with no condensation

Standard accessories

White calibration plate, Target mask Ø 8 mm, Target mask Ø 3 mm , RS-232C cable, AC adapter,AA-size battery (×4)

Optional Accessories

Hard case, Dust cover set, Dust cover, SpectraMagic™NX (software), Zero calibration box.

 


PDF Dosyasını İndir