KONICA MINOLTA

3D Ölçüm Cihazi

Konica Minolta Non Contact 3D Digitizer-Range7

Measuring method Triangulation by light sectioning method Light source Semiconductor laser, Wavelength: 660 nm Laser class Class 2 (IEC 60825-1 Edition 2) Number of pixels taken 1.31 megapixels (1280 × 1024) Measurement distance 450 to 800 mm Receiving lens TELE, WIDE Measurement range (Units: mm) Distance TELE 450 mm TELE 800 mm WIDE 450 mm WIDE 800 mm     Direction X × Y 79 × 99 141 × 176 150 × 188 267 × 334     Z 54 97 109 194     XY direction measurement interval (Units: mm) 0.08 0.14 0.16 0.28     Accuracy (Distance between balls)*1 ±40 µm Precision (Z, σ)*2 4 µm Auto-focus Provided Auto-exposure Provided Scan time Approx. 2 sec. or more (1 scan) Preview function Approx. 0.4 sec./scan Scanning ambient lighting condition 500 lx or less Output interface USB 2.0 High Speed Power Included AC Adapter Input voltage: 100 to 240 VAC (50/60 Hz) Rating: 1.4 A (at 100 VAC input) Dimensions 295 (W) × 190 (H) × 200 (D) mm (Excluding grips and lens) Weight Approx. 6.7 kg Operating temperature/humidity range 10 to 40 °C; Relative humidity 65% or less (no condensation) Storage temperature/humidity range -10 to 40°C; Relative humidity 85% or less (at 35°C, no condensation) PDF Dosyasını İndir

Konica Minolta Non Contact 3D Digitizer -VI-9i

Principal Specifications Type Non-contact 3D digitizer Measuring Method Triangulation light block method Light-Receiving Lenses (Interchangeable) TELE Focal distance f=25 mm MIDDLE Focal distance f=14 mm WIDE Focal distance f=8 mm Scan Range 0.6 to 1.0 m (In Standard mode) 0.5 to 2.5 m (In Extended mode) Laser Scan Method Galvanometer-driven rotating mirror Laser Class Class 2 (IEC60825-1), Class 1 (FDA) X Direction Input Range (In Extended mode) TELE 93 to 463 mm MIDDLE 165 to 823 mm WIDE 299 to 1495 mm Y Direction Input Range (In Extended mode) TELE 69 to 347 mm MIDDLE 124 to 618 mm WIDE 224 to 1121 mm Z Direction Input Range (In Extended mode) TELE 26 to 680 mm MIDDLE 42 to 1100 mm WIDE 66 to 1750 mm Accuracy (X,Y,Z) ±0.05 mm (Using TELE lens at distance of 0.6 m, with Field Calibration System, Konica Minolta's standard, at 20°C) Precision (Z, σ ) 0.008 mm (Using TELE lens at distance of 0.6 m, Konica Minolta's standard, at 20°C) Input Time (per scan) 2.5 sec Transfer Time to Host Computer Approx. 1.5 sec Ambient Lighting Condition Office environment, 500 lx or less Imaging Element 3D data: 1/3-inch frame transfer CCD (340,000 pixels) Color data: Common with 3D data (color separation by rotary filter) Number of Output Pixels 3D data/Color data: 640 x 460 Output Format 3D data: Konica Minolta format, & (STL,DXF, OBJ, ASCII points, VRML) (Converted to 3D data by the Polygon Editing Software/ standard accessory) Color data: RGB 24-bit raster scan data Data File Size Total 3D and color data capacity: 3.6MB per data Viewfinder 5.7-inch LCD (320 × 240 pixels) Output Interface SCSI II (DMA synchronous transfer) Power Commercial AC power, 100 to 240 V (50/60Hz), rated current 0.6 A (at 100 VAC) Dimensions 221 (W) × 412 (H) × 282 (D) mm Weight Approx. 15 kg (with lens attached) Operating temperature/humidity range 10°C to 40°C, relative humidity 65% or less with no condensation Storage temperature/humidity range 0°C to 40°C, relative humidity 85% or less (at 35°C) with no condensation Regulatory approvals UL 61010A-1, CSA-C22.2 No.1010-1, etc.   PDF Dosyasını İndir

Konica Minolta Non Contact 3D Digitizer -VIVID 910

Principal Specifications Model Non-contact 3D digitizer VI-910 Measurement method Triangulation light block method Autofocus Image surface AF (contrast method); active AF Light-receiving lenses (Exchangeable) TELE: Focal distance f=25mm MIDDLE: Focal distance f=14mm WIDE: Focal distance f=8mm Scan range (depth of field) 0.6 to 2.5m (2m for WIDE lens) Optimal 3D measurement range 0.6 to 1.2m Laser class Class 2 (IEC60825-1), Class 1 (FDA) Laser scan method Galvanometer-driven rotating mirror X-direction input range (varies with distance) 111 to 463mm (TELE), 198 to 823mm (MIDDLE), 359 to 1196mm (WIDE) Y-direction input range (varies with distance) 83 to 347mm (TELE), 148 to 618mm (MIDDLE), 269 to 897mm (WIDE) Z-direction input range (varies with distance) 40 to 500mm (TELE), 70 to 800mm (MIDDLE), 110 to 750mm (WIDE/FINE mode) Accuracy X: ±0.22mm, Y: ±0.16mm, Z: ±0.10mm to the Z reference plane (Conditions: TELE/FINE mode, Konica Minolta's standard) Input Time 0.3s (FAST mode), 2.5s (FINE mode), 0.5s (COLOR) Transfer time to host computer Approximately 1s (FAST mode) or 1.5s (FINE mode) Ambient lighting condition 500 lx or less Imaging element 3D data: 1/3 inch frame-transfer CCD (340,000 pixels) Color data: 3D data is shared (color separation by rotary filter) Number of output pixels 3D data: 307,000 (FINE mode), 76,800 (FAST mode) Color data: 640 × 480 × 24 bits color depth Output format 3D data: Konica Minolta format (& STL, DXF, OBJ, ASCII points, VRML; converted into 3D data by Polygon Editing Software provided as a standard accessory) Color data: RGB, 24-bit raster scan data Recording medium Compact flash memory card (128MB) Data file size Total 3D data and color data capacity: 1.6MB (FAST mode) per data, 3.6MB (FINE mode) per data Viewfinder 5.7-inch LCD (320 × 240 pixels) Output interface SCSI II (DMA synchronous transfer) Power Commercial AC power 100V to 240V (50 or 60Hz), rated current 0.6A (at 100V) Dimensions (W × H × D) 213 × 413 × 271mm (8-3/8 × 16-1/4 × 10-11/16 in.) Weight Approx. 11kg (25 lbs.) Operating temperature/humidity range 10 to 40°C, relative humidity 65% or less with no condensation Storage temperature/humidity range -10 to 50°C, relative humidity 85% or less (at 35°C) with no condensation   PDF Dosyasını İndir

Isik Ölçüm Cihazi

Konica Minolta Illuminance Meter-T-10

Specifications Principal Specifications T-10 Series Model Illuminance meter T-10 Illuminance meterT-10M Type Multi-function digital illuminance meter with detachable receptor head Receptor Silicon photocell Relative Spectral Response* Within 6% (f1´) of the CIE spectral luminous efficiency V (λ) Cosine Correction Characteristics Within ±1% at 10° ; Within ±2% at 30° ; Within ±6% at 50° ; Within ±7% at 60° ; Within ±25% at 80° Illuminance units Lux (lx) or foot candles (fcd) (switchable) Measuring range Auto range (manual 5 range at the time of analog output) Measuring function Illuminance(lx). illuminance difference(lx). illuminance ratio(%). integrated illuminance(lx·h). integration time(h). average illuminance(lx). Measuring range Illuminance 0.01 to 299,900 lx 0.001 to 29,990 fcd Integrated illuminance 0.01 to 999,900 × 103 lx·h 0.001 to 99,990 × 103 fcd·h / 0.001 to 9999 h User calibration function CCF(Color Correction Factor) setting function Accuracy ±2% ±1digit of displayed value (based on Konica Minolta standard) Temperature/humidity drift Within ±3% ±1digit (of value displayed at 20°C/68°F ) within operating temperature/humidity range Digital output RS-232C Analog output 1mV/digit,3V at maximum reading; Output impedance: 10KΩ; 90% response time: FAST setting: 1ms, SLOW setting: 1s Display 3 or 4 Significant-digit LCD with back-light illumination Operating temperature /humidity range -10 to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature /humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation Power source 2 AA-size batteries / AC adapter (optional) Battery life 72 hours or longer (when alkaline batteries are used) in continuous measurement Dimensions 69 × 174 × 35 mm (2-6/16×6-14/16×1-7/16 in.) Main body : 69 × 161.5 ×30 mm (2-6/16×6-6/16×1-3/16 in.) Receptor : Ø 16.5 × 12.5 (Ø 11/16 × 1/2 in.) Cord length : 1 m ( 3.3 in.) Weight 200 g (7.0 oz.) without battery 205 g (7.2 oz.) without battery Standard accessories Ø 3.5 mm (Ø 1/8 in.) subminiature plug for analog output ; Receptor cap ; Neck strap ; Case ; Battery Ø 3.5 mm (Ø 1/8 in.) subminiature plug for analog output ; Neck strap ; Case ; Battery Optional accessories Receptor head ; Adapter for Multi-point ; AC Adapter ; Data processing software  

Konica Minolta Incident Color Meter CL-200

Specifications Principal Specifications CL-200 Model Incident Color Meter CL-200 Relative spectral response Closely matches CIE standard observer curves x–(λ), y–(λ), and z–(λ) Within 8% (f1') of the CIE spectral luminous efficiency V(λ) Receptor Silicon photocell Measurement functions Tristimulus values: XYZ   Chromaticity coordinates: Ev xy, Ev u'v'   Correlated color temperature: Ev, Tcp, Δuv   Color difference: Δ(XYZ), Δ(Ev xy), Δ(Ev u'v'), ΔEvΔu'v' (One target color)   Other functions User calibration function, Data hold function, Multi-point measurement (2 to 30 receptors) Measuring range 0.1 to 99,990 lx, 0.01 to 9,999 fcd (Chromaticity: 5 lx, 0.5 fcd or above) in four automatically selected ranges Accuracy Ev: ±2%, ±1 digit of displayed value (based on Konica Minolta standard) xy: ±0.002 (800 lx, Standard Illuminant A measured) Repeatability Ev: 0.5% ±1 digit (2σ) xy: ±0.0005 (800 lx, Standard Illuminant A measured) Temperature drift Ev: ±3%, ±1 digit of displayed value xy: ±0.003 Humidity drift Ev: ±3%, ±1 digit of displayed value xy: ±0.003 Response time 0.5 sec. (continuous measurement) Digital output RS-232C Display 4 Significant-digit LCD with back-light illumination Operating temperature/humidity range -10 to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation Power source 2 AA-size batteries / AC adapter (optional) Battery life 72 hours or longer (when alkaline batteries are used in continuous measurement Dimensions 69 × 174 × 35 mm (2-3/4 × 6-7/8 × 1-3/8 in.) Weight 215 g (7.6 oz) not including batteries Standard accessories Soft case, lens cap, neck strap, batteries Optional accessories Additional receptors, Adapter Unit for Main Body T-A20; Adapter Unit for Receptor Head T-A21; AC Adapter AC-A10 (AC-A10N in North America); Data Management Software CL-S1w; Printer Cable T-A12; Connecting Cable T-A11 (for PC); Hood CL-A11; Hard Case CL-A10  

Konica Minolta Luminance Meter-LS-100 & LS-110

Specifications Principal Specifications LS-100/LS-110 Model Luminance Meter LS-100 Luminance Meter LS-110 Type SLR spot luminance meter for measuring light-source and surface brightness Acceptance angle 1° 1/3° Optical system 85mm f/2.8 lens; SLR viewing system; flare factor less than 1.5% Angle of view 9° Focusing distance 1014mm (40 in.) to infinity Minimum measuring area Ø 14.4 mm Ø 4.8 mm Receptor Silicon photocell Relative Spectral Response* Within 8% (f1´) of the CIE spectral luminous efficiency V (λ) Response time FAST: Sampling time: 0.1s, time to display: 0.8 to 1.0s; SLOW: Sampling time: 0.4s, time to display: 1.4 to 1.6s Luminance units cd/m2 or fL (switchable) Measuring range FAST: 0.001 to 299,900 cd/m2 (0.001 to 87,530fL) SLOW: 0.001 to 49,990 cd/m2 (0.001 to 14,590fL) FAST: 0.01 to 999,900 cd/m2 (0.01 to 291,800fL) SLOW: 0.01 to 499,900 cd/m2 (0.01 to 145,900fL) Accuracy 0.001 to 0.999 cd/m2 (or fL): ±2% ±2 digits of displayed value 1.000 cd/m2 (or fL) or greater: ±2% ±1 digit of displayed value 0.01 to 9.99 cd/m2 (or fL): ±2% ±2 digits of displayed value 10.00 cd/m2 (or fL) or greater: ±2% ±1 digit of displayed value (Illuminant A measured at ambient temperature of 20 to 30°C/68 to 86°F) Repeatability 0.001 to 0.999 cd/m2 (or fL): ±0.2% ±2 digits of displayed value 1.000 cd/m2 (or fL) or greater: ±0.2% ±1 digit of displayed value 0.01 to 9.99 cd/m2 (or fL): ±0.2% ±2 digits of displayed value 10.00 cd/m2 (or fL) or greater: ±0.2% ±1 digit of displayed value (Measurement subject: Illuminant A) Temperature/humidity drift Within ±3% ±1 digit (of value displayed at 20°C/68°F) within operatingtemperature /humidity range Calibration mode Minolta standard/user-selected standard (switchable) Color correction factor Set by numerical input; range: 0.001 to 9.999 Reference luminance 1; set by measurement or numerical input Measurement modes Luminance; luminance ratio; peak luminance or luminance ratio Display External: 4-digit LCD with additional indications Viewfinder: 4-digit LCD with LED backlight Data communication RS-232C; baud rate: 4800bps External control Measurement process can be started by external device connected to data output terminal Power source One 9V battery Power consumption While measuring button is pressed and viewfinder display is lit: 16 mA average While power is on and viewfinder display is not lit: 6 mA average Operating temperature/humidity range 0 to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature /humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation Dimensions 79×208×150 mm (3-1/8×8-3/16×5-7/8 in.) Weight 850 g (30 oz.) without battery Standard accessories Lens cap; Eyepiece cap; ND eyepiece filter; 9V battery; Case  

Konica Minolta UV Radiometer-UM-10

Introduction Hand-held and easy to use UV Radiometer for various applications The recording of the strength of ultraviolet radiation and radiation is the task of the Konica Minolta UV radiometer. UV radiation is used in many areas of product development and production, such as food technology, agricultural technology, or in the production of semiconductors. UV radiation is even used in medicine and cosmetics; the best-known application may be the sun bed. UV radiometers capture this radiation and help with control as well in research and development. Background knowledge The strength of UV radiation is measured in W/m2 (or μW/cm2) and is equivalent to the illumination strength in lux, which is measured with lux meters. It indicates how much UV radiation strikes a defined surface. The radiation indicates the amount of UV radiation in J/m2 (Joule per square meter) or mJ/cm2 that hits a surface over a specific time frame and is the radiant physical equivalent to exposure. UM-10 Display unit The UM-10 is a small, handy, modularly constructed instrument with a choice of three receptor heads to record UV radiation in the spectral area of 220 nm to 480 nm. Within this wide measurement range of 0.1 to 199,900 μW/cm2, the UM-10 switches the measurement range automatically and indicates readings on the large LCD. A digital (RS-232C) as well as an analogue output enables the measurement values to be exported to a PC and other instruments. Depending on the measurement task and/or the spectral area to be measured, an appropriate receptor head is chosen and attached to the basic UM-10 unit. Receptor Head UM-250 The receptor head UM-250 captures "hard" UV radiation in the area of 220 nm - 300 nm with a centre of gravity wavelength of about 250 nm. Receptor Head UM-360 The receptor head UM-360 captures "soft" UV radiation in the area of 310 nm -400 nm with a centre of gravity wavelength of about 365 nm. Receptor Head UM-400 The receptor head UM-400 captures UV and blue radiation in the area of 360 nm - 480 nm with a centre of gravity wavelength of about 415 nm.

Medikal Ölçüm Cihazi

Konica Minolta Pulse Oximeter-Pulsox-2

Principal Specifications Measuring method Dual-wavelength pulse-type oximeter Measuring range SpO2: 0 to 100% Pulse rate: 20 to 250 bpm Accuracy SpO2: ± 2% (70 to 100% , 1 s.d.) Pulse rate: ± 2 bpm Display Oxygen saturation (SpO2) Pulse rate number Pulse level meter Error messages Equipment Classification Protection against electric shock: Internally powered Type of applied Part: BF Splash-proof equipment: not designed to be submerged into water. Not suitable for use in the presence of flammable anesthetic mixture with air or oxygenornitrous oxide. Mode of operation: Continuous Operation temperature / humidity range 0 to 40°C (32 to 104°F) 30 to 95% relative humidity with no condensation Storage temperature / humidity range -10 to 60°C (14 to 140°F) 30 to 95% relative humidity with no condensation Power 2 AAA-size batteries Dimensions (W × H × D) 69 × 60 × 28 mm (2-11/16 × 2-3/8 × 1-1/8 in.) Weight (without batteries) 57 g (2 oz.) Accessories Standard Accessory; Neck strap  

Konica Minolta Pulse Oximeter-Pulsox-300 & Pulsox-300i

Main specifications Dual-wavelength pulse type (665nm/880nm) arterial blood oxygen saturation measuring instrument Name: Oxygen Saturation Monitor Model name PULSOX-300 PULSOX-300i     PULSOX-300 PULSOX-300i Functions Measuring range SpO2: 0 to 100% SpO2 Pulse rate : 30 to 230 bpm Accuracy SpO2: ±2% SpO2 (70 to 100% range, 1S.D.) Pulse rate: ±2 bpm (30 to 100 range) or ±2% of value (100 to 230 range) Display Display type: LED display Oxygen saturation (SpO2), Pulse rate, Pulse level meter (5 steps), Battery indication, Error messages indication Display type: Liquid crystal display (with back-light function) Oxygen saturation (SpO2), Pulse rate number, Pulse level meter (9 steps), Battery indication (3 steps), Error messages indication Warning functions SpO2: Low SpO2 warning (flashing display), Battery indication (flashing when the battery is nealy empty), Error message indication SpO2: Low SpO2 warning (flashing display), Battery indication, Error message indication Memory function (Up to 300 hours at one-second intervals) - Oxygen saturation (SpO2), pulse rate, measurement date/time Operating conditions temperature/humidity range 0 to 40°C (32 to 104°F); 30 to 85% relative humidity with no condensation atmospheric pressure/altitude range  700 to 1060hPa (altitude: –400 to 3000m) Storage conditions temperature/humidity range –10 to 60°C (14 to 140°F); 10 to 95% relative humidity with no condensation atmospheric pressure/altitude range 700 to 1060hPa (altitude: –400 to 3000m) Power 1 AAA-size battery 1.5V , 100mW (Service life under continual usage: approx. 16 hours with alkaline battery) 1 AAA-size battery 1.5V , 60mW (Service life under continual usage: approx. 30 hours with alkaline battery) Dimensions (W × H × D) 68 × 58 × 15 mm Weight 56 g (including battery/excluding wrist band and probes) Usable life 6 years [Verified by KONICA MINOLTA SENSING, INC. (based on own data)]   PDF Dosyasını İndir

Renk Analiz Cihazi

Konica Minolta Pulse Oximeter-Pulsox-300 & Pulsox-300i

Specifications Principal Specifications CA-2000 Lens Standard lens Wide lens Telephoto lens* Light receptor 2/3-inch CCD image sensor (monochrome); Effective number of pixels: 1000×1000 (Measurement points: 980×980); Equipped with XYZ filter (closely matches CIE 1931 color-matching functions) and ND filter Typical measurement sizes/distances (Approx. length per side of square/distance) 98 mm/250 mm 145 mm/200 mm 115 mm/900 mm 210 mm/500 mm 410 mm/500 mm 275 mm/2000 mm 440 mm/1000 mm 850 mm/1000 mm 420 mm/3000 mm 890 mm/2000 mm 1770 mm/2000 mm With low-magnification macro ring: 57 mm/500 mm With high-magnification macro ring: 27 mm/300 mm Measurement luminance range (including when ND filter is used) 0.1 to 100,000 cd/m² 0.5 to 100,000 cd/m²(1 to 100,000 cd/m² when high-magnification macro ring is used) Size Body only 160 (W)×164 (H)×199 (D) mm (Height including handle: 211 mm) With lens/lens hood attached 224 (D) mm 219 (D) mm 224 (D) mm With low-magnification macro ring: 230 (D) mm With high-magnification macro ring: 237 (D) mm Weight Approx. 3.5 kg (when Standard lens and lens hood are attached) Power source Included AC adapter: 100 to 240V AC, 50/60Hz   PDF Dosyasını İndir

Konica Minolta CRT Color Analyzer-CA-100Plus

Specifications Principal Specifications CA-100Plus   CA-100Plus (Measuring Probe) CA-100Plus (High Luminance Measuring Probe) Detector Silicon photocell Silicon photocell Measurement diameter Ø 21 mm Ø 21 mm Display range Luminance 0.01 to 1000 cd/m2 0.01 to 2000cd/m2 Chromaticity Displayed in 4- or 3-digit values (selectable) Displayed in 4- or 3-digit values (selectable) Luminance Measurement range 0.05 to 1000 cd/m2 0.05 to 2000 cd/m2 Accuracy (for white)*1 ±2%, ±1 digit of reading (Temperature: 23°C±2°C, Relative humidity: (40±10)%) ±2%, ±1 digit of reading (Temperature: 23°C±2°C, Relative humidity: (40±10)%) Repeatability*1 0.05 to 1000 cd/m2 0.2%+1 digit (2σ) 0.05 to 2000 cd/m2 0.2%+1 digit (2σ) Chromaticity Measurement range 0.05 to 1000 cd/m2 0.05 to 2000 cd/m2 Accuracy*1 0.05 to 0.19 cd/m2 ±0.006 for white; 0.20 to 0.49 cd/m2 ±0.004 for white; 0.50 to 1000 cd/m2 ±0.003 for white; 40.00 cd/m2 ±0.002 for white, ±0.004 for monochrome*2 0.05 to 0.09 cd/m2 ±0.008 for white; 0.1 to 0.39 cd/m2 ±0.006 for white; 0.40 to 0.99 cd/m2 ±0.004 for white; 1.00 to 2000 cd/m2 ±0.003 for white; 40.00 cd/m2 ±0.002 for white, ±0.004 for monochrome*2 Repeatability*1 0.05 to 0.19 cd/m2 0.006 (2σ); 0.20 to 0.49 cd/m2 0.002 (2σ); 0.50 to 1000 cd/m2 0.001 (2σ) 0.05 to 0.09 cd/m2 0.009 (2σ); 0.1 to 0.39 cd/m2 0.006 (2σ); 0.40 to 0.99 cd/m2 0.002 (2σ); 1.00 to 2000 cd/m2 0.001(2σ) Measurement speed*3 xyLv 0.05 to 0.99 cd/m2 5 (4.5) meas./sec.*4 ; 1.00 to 1000 cd/m2 20 (17) meas./sec.*4 0.05 to 1.99 cd/m2 5 (4.5) meas./sec.*4 ; 2 to 2000 cd/m2 20 (17) meas./sec.*4 Display Digital xyLv, TΔuvLv, RGB, XYZ, u'v'Lv xyLv, TΔuvLv, RGB, XYZ, u'v'Lv Analog Δ x, Δ y, Δ Lv, R/G, B/G, Δ G, Δ R, B/R, G/R SYNC mode NTSC, PAL, EXT, UNIV, INT NTSC, PAL, EXT, UNIV, INT Object under measurement Vertical synchronous frequency: 40 to 200Hz Vertical synchronous frequency: 40 to 200Hz Memory channels 100 100 Analyzer function Standard function Standard function Interface USB (Version 1.1) or RS-232C (38,400bps or below) USB (Version 1.1) or RS-232C (38,400bps or below) Multi-point measurement Max. 5 points (Use 4-Probe Expansion Board CA-B04.) Max. 5 points (Use 4-Probe Expansion Board CA-B04.) Operating temperature/humidity range Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation Luminance change: ±2% ±1 digit of reading for white Chromaticity change: ±0.002 for white, 0.006 for monochrome (from reading of Konica Minolta's standard CRT*1, 40.00cd/m2, at 23°C, 40% Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation Luminance change: ±2% ±1 digit of reading for white Chromaticity change: ±0.002 for white, 0.006 for monochrome (from reading of Konica Minolta's standard CRT*1, 40.00cd/m2, at 23°C, 40% Storage temperature/humidity range 0 to 28°C: Relative humidity 70% or less with no condensation 28 to 40°C: Relative humidity 40% or less with no condensation 0 to 28°C: Relative humidity 70% or less with no condensation 28 to 40°C: Relative humidity 40% or less with no condensation Input voltage range 100 to 240V~, 50 to 60Hz, 50VA 100 to 240V~, 50 to 60Hz, 50VA Dimensions (W × H × D) Main unit, Probe 340 × 127 × 216 mm, Ø 45 × 142 mm 340 × 127 × 216 mm, Ø 45 × 142 mm Weight Main unit, Probe 3.58 kg, 285 g 3.58 kg, 285 g   PDF Dosyasını İndir

Konica Minolta Display Color Analyzer-CA-210

Specifications Principal Specifications CA-210 Receptor Silicon photocell Measurement area Ø 27mm Acceptance angle ±2.5°; Pointing function: By LED Measurement distance 30±10 mm Display range Luminance 0.01 to 1000 cd/m2 Chromaticity Displayed in 4- or 3-digit value (selectable) Luminance Measurement range 0.10 to 1000 cd/m2 Accuracy (for white) *1 ±2%, ±1 digit of reading (Temperature: 23°C ±2°C; Relative humidity:(40±10)%) Repeatability (2σ) *1 0.10 to 0.99 cd/m2: 0.2%+1digit; 1.0 to 1000 cd/m2: 0.1%+1digit Chromaticity Measurement range 0.10 to 1000 cd/m2 Accuracy *1 0.10 to 4.99 cd/m2: ±0.008 for white 5.00 to 39.99 cd/m2: ±0.005 for white 40.00 to 1000 cd/m2: ±0.003 for white 160 cd/m2: ±0.002 for white; ± 0.004 for monochrome *2 Repeatability (2σ) *1 0.10 to 0.19 cd/m2: 0.015 0.20 to 0.49 cd/m2: 0.008 0.50 to 1.99 cd/m2: 0.003 2.00 to 1000 cd/m2: 0.001 Measurement speed (meas./sec.) xyLv*3 0.10 to 1.99 cd/m2: 5 (4.5) 4 cd/m2 or greater: 20 (17) Display Digital xyLv, XYZ, TΔuvLv, u'v'Lv, RGB analyze Analog ΔxΔyΔLv, R/G B/G ΔG, ΔR B/R G/R LCD 16 characters × 2 lines (with backlight) SYNC mode NTSC, PAL, EXT, UNIV, INT Measurement subject Vertical synchronous frequency: 40 to 200Hz Memory channels 100 Analyzer function Standard function Interface USB (Rev. 1.1) or RS-232c (38,400 bps maximum) Multi-point measurement Max. 5 points (using optional 4-Probe Expansion Board CA-B14) Software Solutions SDK software (supplied as standard accessory) Operating temperature/humidity range Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation. Luminance change: ±2% ±1 digit of reading for white; Chromaticity change: ±0.002 for white, ±0.006 for monochrome from reading of Konica Minolta's standard LCD *1, 160.0 cd/m2 at 23°C 40%RH Storage temperature/humidity range 0 to 28°C: Relative humidity 70% or less with no condensation; 28 to 40°C: Relative humidity 40% or less with no condensation Input voltage range 100 to 240V~50/60Hz, 50VA Dimensions (W × H × D) Main body: 340 × 127 × 216 mm Probe: Ø 49 × 204 mm Weight Main body: 3.58 kg; Probe: 520 g   PDF Dosyasını İndir

Konica Minolta Luminance & Color Meter-CS-100A

Specifications Principal Specifications CS-100A Type SLR spot colorimeter for measuring light-source and surface luminance and chromaticity Acceptance angle 1° Optical system 85 mm f/2.8 lens; SLR viewing system; flare factor less than 1.5% Angle of view 9° with 1° measurement area indication Focusing distance 1014 mm (40 in.) to infinity Receptors 3 silicon photocells filtered to detect primary stimulus values for red, green, and blue light Spectral response Closely matches CIE 1931 Standard Observer curves Response time FAST: Sampling time: 0.1s, Time to display: 0.8 to 1.0s; SLOW: Sampling time: 0.4s, Time to display: 1.4 to 1.6s Luminance units: cd/m2 or fL (switchable) Measuring range FAST: 0.01 to 299,000 cd/m2 (0.01 to 87,530fL); SLOW: 0.01 to 49,900 cd/m2 (0.01 to 14,500fL) Accuracy Luminance (Y): ±2% of reading ±1 digit Chromaticity (x,y): ±0.004 (Illuminant A measured at ambient temperature of 18 to 28°C/64 to 82°F) Repeatability Luminance (Y): ±0.2% of reading ±1 digit Chromaticity (x,y): FAST: Y 100 cd/m2 or above: ±0.001; 48.1 to 99.9 cd/m2: ±0.002; Below 48.1 cd/m2: Below measurement range SLOW: Y 25.0 cd/m2 or above: ±0.001; 12.0 to 24.9 cd/m2: ±0.002; Below 12.0 cd/m2: Below measurement range (Measurement subject: Illuminant A) Target value 1; set by measurement or numerical input Measurement modes Absolute color: Yxy; Color difference: Δ(Yxy) Display External: LCD; 3 values (Y, x, and y) of 3 digits each with additional indications Viewfinder: 3-digit LCD (showing luminance value y ) with LED backlight Data communication RS-232C; baud rate: 4800bps External control Measurement process can be started by external device connected to data output terminal Power source One 9V battery; Power can also be supplied via data output terminal Operating temperature/humidity range 0 to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation Dimensions (W × H × D) 79 × 208 × 154 mm (3-1/8 × 8-3/16 × 6-1/16 in.) Weight 890 g (2 lb.) without battery Standard accessories Lens cap; Eyepiece cap; Protective filter; ND eyepiece filter; 9V battery; Chromaticity chart; Case  

Konica Minolta Luminance & Color Meter-CS-200

Specifications Principal Specifications CS-200 Model CS-200 Measurement range 0.01 - 200,000 cd/m2 (Measuring angle 1°) 0.01 - 5,000,000 cd/m2 (Measuring angle 0.2°) 0.01 - 20,000,000 cd/m2 (Measuring angle 0.1°) Accuracy (Measuring angle 1°) #1 (Temperature: 23°C±2°C, Relative humidity: 65% max.) 150 cd/m2 ( for Illuminant A ) : Lv ±2 % ±1digit ; xy ±0.002 0.01-0.5 cd/m2 ( for Illuminant A ) : Lv ±0.02 cd/m2 ±1digit ; 0.5-1 cd/m2 ( for Illuminant A ) : Lv ±0.02 cd/m2 ±1digit ; xy ±0.007 1-10 cd/m2 ( for Illuminant A ) : Lv ±2 % ±1digit ; xy ±0.004 10-200,000 cd/m2 ( for Illuminant A) : Lv ±2 % ±1digit ; xy ±0.003 5000 cd/m2 ( for Illuminant A ) : color filter (R, G, B) ; xy ±0.006 Repeatability (Measuring angle 1°) #2 0.01-1 cd/m2 ( for Illuminant A ) : Lv ±0.01 cd/m2 ±1digit ;(2σ/AUTO) 1-2 cd/m2 ( for Illuminant A ) : Lv ±0.5 % ±1digit ; xy 0.002 (2σ/AUTO) 2-4 cd/m2 ( for Illuminant A ) : Lv ±0.5 % ±1digit ; xy 0.001 (2σ/AUTO) 4-8 cd/m2 ( for Illuminant A ) : Lv ±0.5 % ±1digit ; xy 0.0005 (2σ/AUTO) 8-200,000 cd/m2 ( for Illuminant A ) : Lv ±0.1% ±1digit ; xy 0.0004 (2σ/AUTO) Measurement time Automatic setting between 1s and 60s (AUTO); Automatic setting to 1s or 3s (LTD. AUTO) 0.5 sec / meas. (Super-FAST) 1 sec / meas.(FAST) 3 sec / meas. (SLOW) 12 sec / meas. (Super-SLOW) Measurement method Spectral method, Grating + linear photo diode array Measuring angle 1°, 0.2°, 0.1°(switchable) Minimum measuring area 0.5 mm 0.1 mm (close up lens) Minimum measuring distance 296 mm (Distance from front edge of metal lens barrel) Observer 2/10 degrees Color space Lv x y, Lv u' v', Lv TΔuv, XYZ, dominant wavelength Measurement synchronization setting range Vertical synchronization frequency : 40.00 to 200.00Hz Interface USB 1.1 Power source AC adapter or 4 AA-Size Batteries Battery life Approx. 3 hours (continuous measurement / Fast mode / AA-size alkaline cells) Size 95 mm (W) × 127 mm (H) × 330 mm (L) Weight 1.8 kg (without battery) Operating temperature/humidity range 0°C to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature /humidity range 0°Cto 45°C,relative humidity 85% or less (at 35°C)with no condensation  

Konica Minolta Spectroradiometer-CS-2000

Specifications Principal Specifications CS-2000 Model CS-2000 Wavelength range 380 to 780 nm Wavelength resolution 0.9 nm/pixel Display wavelength bandwidth 1.0 nm Wavelength precision ±0.3 nm (median wavelength: 435.8 nm, 546.1 nm, 643.8 nm Hg-Cd lamp) Spectral bandwidth 5 nm or less (half bandwidth) Measuring angle (selectable) 1° 0.2° 0.1° Measurement luminance range (Illuminant A) 0.003 to 5,000 cd/m2 0.075 to 125,000 cd/m2 0.3 to 500,000 cd/m2 Minimum luminance display 0.00002 cd/m2 Accuracy: Luminance (Illuminant A) *1 ±2% Accuracy: Chromaticity (Illuminant A)*1 x,y :±0.003 (0.003 to 0.005 cd/m2) x,y :±0.002 (0.005 to 0.05 cd/m2) x :±0.0015 (0.05 cd/m2 to) y :±0.001 x,y :±0.003 (0.075 to 0.125 cd/m2) x,y :±0.002 (0.125 to 1.25 cd/m2) x :±0.0015 (1.25 cd/m2 to ) y :±0.001 x,y :±0.003 (0.3 to 0.5 cd/m2) x,y :±0.002 (0.5 to 5 cd/m2) x :±0.0015 (5 cd/m2 to ) y :±0.001 Repeatability: Luminance(2σ) 0.4 % (0.003 to 0.05 cd/m2) 0.3 % (0.05 to 0.1 cd/m2) 0.15 % (0.1 to 5,000 cd/m2) 0.4 % (0.075 to 1.25 cd/m2) 0.3 % (1.25 to 2.5 cd/m2) 0.15 % (2.5 to 125,000 cd/m2) 0.4 % (0.3 to 5 cd/m2) 0.3 % (5 to 10 cd/m2) 0.15 % (10 to 500,000 cd/m2) Repeatability: Chromaticity(2σ) 0.002 (0.003 to 0.005 cd/m2) 0.001 (0.005 to 0.1 cd/m2) 0.0006 (0.1 to 0.2 cd/m2) 0.0004 (0.2 to 5,000 cd/m2) 0.002 (0.075 to 0.125 cd/m2) 0.001 (0.125 to 2.5 cd/m2) 0.0006 (2.5 to 5 cd/m2) 0.0004 (5 to 125,000 cd/m2) 0.002 (0.3 to 0.5 cd/m2) 0.001 (0.5 to 10 cd/m2) 0.0006 (10 to 20 cd/m2) 0.0004 (20 to 500,000 cd/m2) Polarization error 1°: 2% or less (400 to 780 nm); 0.1° and 0.2°: 3% or less (400 to 780 nm) Integration time Fast: 0.005 to 16 sec; Normal: 0.005 to 120 sec. Measurement time 2 sec min. (Manual mode) to 243 sec. max. (Normal mode) Color space mode LVxy, Lvu'v', LvTΔuv, XYZ, dominant wavelength, spectral graph Interface USB 1.1 Operating temperature/humidity range 5 to 35°C, relative humidity 80% or less with no condensation Storage temperature/humidity range 0 to 45°C, relative humidity 80% or less with no condensation Size Main unit: 158 (W) × 200 (H) × 300 (D) mm; Lens: Φ70 × 95 mm Weight 6.2 kg   PDF Dosyasını İndir

Konica Minolta Spectroradiometer-CS-2000A

Specifications Principal Specifications CS-2000A Model CS-2000A Measurement angle 0.1°, 0.2°, 1° selectable Measurement wavelength range 380 to 780nm Wavelenght resolution 0.9nm/pixel Display wavelength pitch 1.0nm Median wavelength precision ±0.3nm (at 435.8nm, 546.1nm, and 643.8nm) Half bandwidth 5nm or less Luminance measurment range (for Standard illuminant A) 0.1° measurement angle: 0.05 to 500,000 cd/m2 0.2° measurement angle: 0.0125 to 125,000 cd/m2 1° measurement angle: 0.0005 to 5,000 cd/m2 Accuracy Luminance ±2%   Chromaticity (1° measurement angle) x,y: ±0.002 (0.001 to 0.05 cd/m2) x,y: ±0.0015 (from 0.05 cd/m2)   Repeatability Luminance (1°C measurement angle) 1.5% (0.0005 to 0.001 cd/m2) 0.7% (0.001 to 0.003 cd/m2) 0.25% (0.003 to 0.05 cd/m2) 0.15% (0.05 to 5,000 cd/m2)   Chromaticity (1° measurement angle) x: 0.003 y: 0.0035 (0.001 to 0.003 cd/m2) x: 0.001 y: 0.0015 (0.003 to 0.1 cd/m2) x: 0.0006 y: 0.0006 (0.1 to 0.2 cd/m2) x: 0.0004 y: 0.0004 (0.2 to 5,000 cd/m2)   Polarization error 0.1°, 0.2° measurement angle: 3% or less 1° measurement angle: 2% or less Measurement time Approx. 2 to 243 sec. Color space mode Lv x y, Lv u’ v’, Lv TΔuv, XYZ ,spectral waveform, dominant wavelength, excitation purity scotopic luminosity (with CS-S10w Professional) Interface USB 1.1 Operating temperature/humidity range 5 to 30°C; Relative humidity 80% or less with no condensation Power supply AC adapter (100 to 240V~, 50/60 Hz) Dimensions (W × H × D) 158 × 200 × 300mm (Main unit) Ø70 × 95mm (Lens) Weight 6.2kg (including lens)   PDF Dosyasını İndir

Renk Ölçüm CIhazi

Konica Minolta Chlorophyl Meter-SPAD-502

Specifications Principal Specifications SPAD-502 Measurement method Optical density difference at two wavelengths Light source 2 LED's Receptor Silicon photodiode Measurement area 2 × 3 mm Maximum sample thickness 1.2 mm Display LCD Display range -9.9~199 SPAD Repeatability Within ±0.3 SPAD (at 0.0 to 50.0 SPAD) Data Memory 30 data Power supply Two AA-size batteries Battery life Approx. 20,000 measurements with alkaline-manganese batteries Operating range Temperature: 0 - 50°C; Humidity: 85% or less (at 35°C) without condensation Storage temperature/humidity range -20 - 55°C; relative humidity 85% or less (at 35°C) with no condensation Dimensions 164 × 78 × 49 mm (6-7/16 × 3-1/16 × 1-15/16 in.) Weight 225 g (without batteries)   PDF Dosyasını İndir

Konica Minolta Chroma Meter-CR-400 & 410

Specifications Principal Specifications CR-400 / 410 Name Chroma Meters Measuring Head Model CR-400 Head CR-410 Head Illuminating/viewing system d:0° (diffuse illumination/0° viewing angle; specular component included) (compliant with JIS Z 8722; including regular reflectance) Wide-area illumination/0° viewing angle; specular component included) Detector Silicon photocells (6) Display range Y: 0.01% to 160.00% (reflectance) Light source Pulsed xenon lamp Measurement time 1 sec. Minimum measurement interval 3 sec. Battery performance Approx. 800 measurements (when using batteries under Konica Minolta's testing conditions) Measurement/illumination area Ø 8 mm / Ø 11 mm Ø 50 mm/ Ø 53 mm Repeatability Within ΔE*ab 0.07 standard deviation (when the white calibration plate is measured 30 times at intervals of 10 seconds) Inter-instrument agreement ΔE*ab: Within 0.6 Average of 12 BCRA Series II colors ΔE*ab: Within 0.8 Average of 12 BCRA Series II colors Observer condition CIE: 2° Standard Observer Illuminant condition CIE: C, D65 Tolerance judgment* Color difference tolerance (box tolerance and elliptical tolerance) Color space/colorimetric data* XYZ, Yxy, L*a*b*, Hunter Lab, L*C*h, Munsell (Illuminant C only), CMC (l:c), CIE1994, Lab99, LCh99, CIE2000, CIE WI/Tw (Illuminant D65 only), WI ASTM E313 (Illuminant C only), YI ASTM D1925 (Illuminant C only), YI ASTM E313 (Illuminant C only), User index (Up to 6 can be registered from computer) Languages* (Display) LCD: English (default), German, French, Italian, Spanish, Japanese Storable data sets 1,000 (Measuring head and data processor save different data) Color-difference target colors 100 Calibration channels* 20 channels (ch00: White calibration; ch01 to ch19: User calibration ) Display* Chroma values; color difference values; PASS/WARN/FAIL display Interface / Baud rate* RS-232 compliant (for data processor/PC) * Baud rate: 4,800, 9,600, 19,200 (bps); Set at 9600 when shipped from factory Power source Four AAA size alkaline or Ni-MH batteries AC Adapter AC-A305 AC100 - 240 V 50/60Hz Dimensions (W × H × D) 102 × 244 × 63 mm Weight Approximately 550 g (including 4 AAA size batteries and not including RS-232C cable) Approximately 570 g (including 4 AAA size batteries and not including RS-232C cable) Operating temperature/humidity range 0 - 40°C, relative humidity 85% or less with no condensation Storage temperature/humidity range -20 - 40°C, relative humidity 85% or less with no condensation Other LCD backlight ON/OFF function (When on, backlight stays ON for 30 seconds after last key or measurement operation) Standard accessories White Calibration Plate CR-A43; Protective Cap CR-A72; Wrist Strap CR-A73; AC Adapter AC-A305; 4 AAA size batteries White Calibration Plate CR-A44; Protective Cap CR-A72; Wrist Strap CR-A73; AC Adapter AC-A305; 4 AAA size batteries Optional accessories Hard Case CR-A103; RS-232C Cable CR-A102 (for PC); Granular Materials Attachment CR-A50; CR-400 Utility Software CR-S4w; Color Data Software SpectraMagic NX CM-S100w ; Glass Light-Projection Tube CR-A33a/f; Light-Projection Tube CR-A33c/d; Pivoting Base CR-A12 Hard Case CR-A103; RS-232C Cable CR-A102 (for PC); Granular Materials Attachment CR-A50; CR-400 Utility Software CR-S4w; Color Data Software SpectraMagic NX CM-S100w ; Glass Light-Projection Tube CR-A33e   PDF Dosyasını İndir

Konica Minolta Color Reader-CECF-9

Specifications Principal Specifications CECF-9 Illumination / Viewing geometry 8°:di (8° illumination angle / diffuse viewing, specular component included SCI) Receptors 6 silicon photocells (3 for measurement, 3 to control illumination) filtered to detect primary stimulus values for red, green and blue Light source Special halogen lamp for D65 Measuring area Ø 8 mm Display LCD display, 2-rows with 16-characters each Display modes 9 digit of Colour-Code (alphanumerical) with colour difference indications by symbols:   no Sign = ?E*ab max. 1.5   + = ?E*ab 1.5 - 3.0   ++ = ?E*ab min. 3.0 Measuring range L*: 10 - 100 Obserser condition CIE: 10° Standard Observer Illuminant condition CIE: Standard Illuminant D65 Target colour memory 5000 colour data sets Repeatability ?E*ab standard deviation 0.1   Measurement conditions: Average of measurements on standard white plate Min. meas. interval Approx. 1 sec Power source 4 AA-size batteries or optional AC Adapter Adapter AC-A308 Battery life Alkaline-manganese batteries: Approx. 2000 measurements at 10 sec. interval   Ni-Cd batteries: Approx. 600 measurements at 10 sec. interval Operating range Temperature: 0 - 40°C   Humidity: 85% or less (at 35°C) without condensation Weight / Dimensions (W x H x D) 360 g without batteries; 59 x 158 x 85 mm Standard accessories Soft Case CR-A68; Protective Cap incl. white plate CR-A72; Wrist Strap CR-A73; 4 AA-size batteries Optional accessories Data Management Software; Printer Cable CR-A75, Thermo-Printer DPU-H245HS, Data Cable CR-A77; AC Adapter AC-A308   PDF Dosyasını İndir

Konica Minolta Color Reader-CR-10

Specifications Principal Specifications CR-10 Illuminating/viewing geometry 8°:di (8° illumination angle/diffuse viewing, specular component included SCI) Receptors 6 silicon photocells (3 for measurement, 3 to control illumination) Measuring area Approx. Ø 8 mm Display modes ?L*?a*?b* / ?E*ab or ?L*?C*?H* / ?E*ab Target color memory 1 channel; set by measurement Measuring range L*: 10 to 100 Observer CIE: 10° Standard Observer Illuminant condition CIE: Standard Illuminant D65 Repeatability Standard deviation within ?E*ab 0.1 (Measurement conditions: Average of measurements of standard white plate) Minimum interval between measurements Approx. 1 sec. Power source Four AA-size batteries or optional AC Adapter AC-A308 Battery life Alkaline-manganese batteries: Approx.2000 measurements at 10-sec. intervals Ni-Cd batteries: Approx. 600 measurements at 10-sec intervals Operating temperature/humidity range 0 - 40°C; relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 - 55°C; relative humidity 85% or less (at 35°C) with no condensation Weight / Dimensions (W x H x D) 360 g without batteries; 59 x 158 x 85 mm Standard accessories Soft Case CR-A68; Protective Cap CR-A72; Wrist Strap CR-A73; AA-size batteries (4) Optional accessories AC Adapter AC-A308; Printer Cable CR-A75   PDF Dosyasını İndir

Konica Minolta Color Reader-CR-11

Specifications Principal Specifications CR-11 Illuminating/viewing geometry 8°:di (8° illumination angle/diffuse viewing, specular component included SCI) Receptors 6 silicon photocells (3 for measurement, 3 to control illumination) Light source Gas filled Tungsten lamp Measuring area Approx. Ø 8 mm Display modes Munsell color space (based on JIS standard color space) Measuring range L*: 10 to 100 Observer CIE: 10° Standard Observer Illuminant condition CIE: Standard Illuminant D65 Repeatability Standard deviation within ?E*ab 0.1 (Measurement conditions: Average of measurements of standard white plate) Minimum interval between measurements Approx. 1 sec. Power source Four AA-size batteries or optional AC Adapter AC-A308 Battery life Alkaline-manganese batteries: Approx.2000 measurements at 10-sec. intervals Operating temperature/humidity range 0 - 40°C; relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 - 55°C; relative humidity 85% or less (at 35°C) with no condensation Weight / Dimensions (W x H x D) 360 g without batteries; 59 x 158 x 85 mm Standard accessories  White Calibration Plate CR-A74, Soft Case CR-A68; Protective Cap CR-A72; Wrist Strap CR-A73; AA-size batteries (4) Optional accessories AC Adapter AC-A308; Printer Cable CR-A75, Thermo-Printer DPU-H245HS  

Konica Minolta Color Reader-CR-14

Specifications Principal Specifications CR-14 Illumination/Viewing geometry 8°:de (8° illumination angle / diffuse viewing, sepular component excluded SCE) Receptors 6 silicon photocells (3 for measurement, 3 to control illumination) Measuring area Approx. Ø 8 mm Display modes Whiteness Index: CIE, Hunter, ASTM E313 Yellowness Index: ASTM E313, ASTM Dl925 Yxy (Displayable in CIE display mode) Observer condition CIE: 10° Standard Observer Illuminant condition CIE: Standard Illuminant D65 Repeatability Standard deviation of Whiteness Index: CIE: 0.5, Hunter: 0.1 (Measurement conditions: When measuring white calibration plate) Minimum interval between measurements Approx. 1 sec. Power source Four AA-size batteries or optional AC Adapter AC-A308 Battery life Alkaline-manganese batteries: Approx.2000 measurements at10-sec. Intervals Ni-Cd batteries: Approx. 600 measurements at 10-sec intervals Operating temperature/humidity range Temperature: 0 - 40°C;relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 - 55°C; relative humidity 85% or less (at 35°C) with no condensation Weight / Dimensions (W x H x D) 360 g without batteries; 59 x 158 x 85 mm Standard accessories White Calibration Plate CR-A74, Soft Case CR-A68; Protective Cap CR-A79; Wrist Strap CR-A73; AA-size batteries (4) Optional accessories Vinyl Cover CR-A80, Printer Cable CR-A75, Thermo-Printer DPU-H245HS, AC Adapter AC-A308   PDF Dosyasını İndir

Konica Minolta Glossmeter-MultiGloss 268

Specifications Specifications Multi Gloss 268 Model MULTI GLOSS 268 Measurement geometry 20°, 60°, 85° Size of measurement spot 20° : 10 × 10 mm 60° : 9 × 15 mm 85° : 5 × 38 mm Standard compliance ISO 2813, ISO 7668, ASTM D 523, ASTM D 2457, DIN 67 530, JIS Z 8741, BS 3900, BS 6161(Part 12) Measurement range 20° : 0.0~2,000 GU 60° : 0.0~1,000 GU 85° : 0.0~160 GU Resolution 0.0~99.9 GU : 0.1 GU 100~2,000 GU : 1 GU Measurement precision Repeatability 0.0~99.9 GU : 0.2 GU 100~2,000 GU : 0.2% of reading Inter Instrument agreement 0.0~99.9 GU : 0.5 GU 100~2,000 GU : 0.5% of reading Memory 999 measurements with date and time Difference measurement Memory for 50 standard Battery performance Approx. 10,000 measurements (when using 1.5 V AA(R6)size alkaline battery) Measurement time 0.5 seconds (each measurement) Power OFF Auto : 10~99 seconds select Languages English,Spanish,German,French,Italian,Japanese Measurement mode Normal mode (Sample mode, Statistics, Continuous, Basic mode), Difference mode Interface RS-232C format Operating temperature /humidity range 15 to 40°Crelative humidity 85% or less (at 35°C) with no condensation Storage temperature /humidity range -10 to 60°C relative humidity 85% or less (at 35°C) with no condensation Power supply 1.5 V AA(R6)size alkaline battery Dimensions 155(W) × 73(H) × 48(D) mm Weight 400 g   PDF Dosyasını İndir

Konica Minolta Glossmeter-Uni Gloss 60 Glossmeter

Specifications Specifications Uni Gloss 60 Model UNI GLOSS 60 Measurement geometry 60° Size of measurement spot 60° : 9 × 15 mm Standard compliance ISO 2813, ISO 7668, ASTM D 523, ASTM D 2457, DIN 67 530, JIS Z 8741, BS 3900, BS 6161(Part 12) Measurement range 60° : 0.0~1,000 GU Resolution 0.0~99.9 GU : 0.1 GU 100~2,000 GU : 1 GU Measurement precision Repeatability 0.0~99.9 GU : 0.2 GU 100~2,000 GU : 0.2% of reading Inter Instrument agreement 0.0~99.9 GU : 0.5 GU 100~2,000 GU : 0.5% of reading Memory 999 measurements with date and time Difference measurement Memory for 50 standard Battery performance Approx. 10,000 measurements (when using 1.5 V AA(R6)size alkaline battery) Measurement time 0.5 seconds (each measurement) Power OFF Auto : 10~99 seconds select Languages English,Spanish,German,French,Italian,Japanese Measurement mode Normal mode (Sample mode, Statistics, Continuous, Basic mode), Difference mode Interface RS-232C format Operating temperature /humidity range 15 to 40°Crelative humidity 85% or less (at 35°C) with no condensation Storage temperature /humidity range -10 to 60°C relative humidity 85% or less (at 35°C) with no condensation Power supply 1.5 V AA(R6)size alkaline battery Dimensions 155(W) × 73(H) × 48(D) mm Weight 400 g  

Konica Minolta Light Cabinet-VeriVide

Specifications Principal Specifications CAC-60 / CAC-120 / CAC-150 Model: CAC-60   Standard Light sources D65, A, F11, UV-B Overall Dimensions (W x H x D) 710 x 570 x 420 mm Viewing Cavity (W x H x D) 680 x 335 x 420 mm Weight 24 kg Model: CAC-120   Standard Light sources D65, A, F11, UV-B Overall Dimensions (W x H x D) 1290 x 780 x 620 mm Viewing Cavity (W x H x D) 1230 x 570 x 590 mm 1230 x 570 x 590 mm Weight 50 kg Model: CAC-150   Standard Light sources D65, A, F11, UV-B Overall Dimensions (W x H x D) 1550 x 780 x 620 mm Viewing Cavity (W x H x D) 1530 x 570 x 590 mm Weight 52 kg Optional accessories for all models 45° tilting table, diffusor  

Konica Minolta Spectrophotometer Bench Top-CM-3220d

Principal Specifications CM-3220d Illumination / Viewing system Reflectance d:8° equipped with simultaneous measurement of SCI (di:8° specular component included) and SCE (de:8° specular component excluded) Conforms to CIE, ISO, ASTME, DIN and JIS Sphere size Ø 52 mm Light receiving element Silicon photodiode array (dual 40 elements) Spectral separation device Diffraction grating Wavelength range, pitch 360-740 nm, 10 nm Halfbandwidth Approx. 10 nm Reflectance range 0-200%, resolution 0.01% Light source 2 pulsed xenon arc lamp Measurement / Illumination area Ø 8 mm / Ø 11 mm Repeatability Spectral Reflectance: Standard deviation within 0.1% (360 to 380 nm within 0.2%) Colorimetric Value: Standard deviation within ΔE*ab 0.04 Measurement conditions: White calibration plate measured 30 times at 10-second intervals after white calibration was performed Inter Instrument agreement Mean ΔE*ab 0.2 (based on 12 BCRA Series II colour tiles) Dimensions (W x H x D) 232 x 115 x 181 mm Weight 4 kg   PDF Dosyasını İndir

Konica Minolta Spectrophotometer Bench Top-CM-3500d

Specifications Principal Specifications CM-3500d Illuminating/viewing system Reflectance: d:8° (diffuse illumination/8° viewing angle); SCI (di:8° specular component included)/SCE (de:8° specular component excluded) switchable; meets IS0 and DIN standards for d:8° geometry; also meets CIE and ASTM standards for d:8° geometry. Transmittance: d: 0° (diffuse illumination/0° viewing angle) Detector Dual 18-element silicon photodiode array with wedge-shaped continuous interference filter Wavelength range 400 to 700 nm Wavelength pitch 20 nm Half bandwidth Approx. 20 nm average Photometric range 0 to 175%; Resolution: 0.01% Light source Pulsed xenon arc lamp Measurement time Approximately 2.5 sec. (to start of data output) Minimum interval between measurements 3 sec. Measurement/illumination diameters Reflectance: Changeable between LAV and MAV LAV: Ø 30 mm measurement / Ø 36 mm illumination MAV: Ø 8 mm measurement / Ø 11 mm illumination Transmittance: Approx. Ø 22 mm Repeatability When white calibration plate is measured 30 times at 10-sec. intervals after white calibration has been performed: Spectral reflectance: Standard deviation within 0.20% Chromaticity: Standard deviation within ΔE*ab 0.05 Inter-instrument agreement Mean ΔE*ab 0.15 (typical) Average for 12 BCRA Series II color tiles compared to values measured with standard body Temperature drift Spectral reflectance: Within ±0.30%/°C Color difference: Within ΔE*ab 0.05/°C Interface RS-232C standard Power AC 100V - 240V 50/60Hz (using included AC adapter) Operating temperature/humidity range 0 - 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 - 45°C, relative humidity 85% or less (at 35°C) with no condensation Dimensions (W × H × D) 413 × 190 × 240 mm Weight 10 kg Standard accessories White Calibration Plate CM-A120; Target Mask (Ø 8 mm) CM-A122; Target Mask (Ø 30 mm) CM-A123; Zero Calibration Box CM-A124; Carrying Case CM-A67; AC Adapter ; RS-232C Cable IF-A12 (2 m) Optional accessories Color Data Software SpectraMagic (tm) NX; CM-A96 Transmittance Specimen Holder; Cells CM-A97 (2 mm), CM-A98 (10 mm), CM-A99 (20 mm); Plastic Cells CM-A130 (2 mm), CM-A131 (10 mm), CM-A132 (20 mm); Transmittance Zero Calibration Plate CM-A100; Sample Viewing Mirror CM-A125; Color Tiles; RS-232C Cable IF-A13 (5 m)   PDF Dosyasını İndir

Konica Minolta Spectrophotometer Bench Top-CM-3600d_3610d

Specifications Principal Specifications CM-3600d / 3610d Illuminating/viewing system Reflectance: d:8° (diffuse illumination/8° viewing angle), capable of simultaneous SCI (di:8° specular component included)/SCE (de:8° specular component excluded) measurement. Conforms to CIE No. 15, ISO 7724/1, ASTM E-1164, DIN 5033 Teil 7, and JIS Z8722 Condition C standards. Transmittance: d:0° (diffuse illumination/0° viewing angle). Conforms to CIE No. 15, ASTM E-1164, DIN 5033 Teil 7 standards Detector Dual 40-element silicon photodiode arrays Spectral separation device Diffraction grating Wavelength range 360 to 740 nm Wavelength pitch 10 nm Half bandwidth Approx. 10 nm Photometric range 0 to 200%; Display resolution: 0.01% Sphere size Ø 152 mm Light source Four pulsed xenon lamps Measurement time Approximately 1.5 seconds (until data output) Minimum interval between measurements Approx. 4 seconds when SCI/SCE measured Measurement/illumination areas Reflectance: Changeable between LAV, MAV, and SAV LAV: Ø 25.4 mm/Ø 30 mm MAV: Ø 8 mm/Ø11 mm SAV: Ø 4 mm/Ø 7 mm Transmittance: Approx. Ø 22 mm Repeatability Spectral reflectance: Standard deviation within 0.1% Colorimetric values: Standard deviation within ΔE*ab 0.02 Inter instrument agreement Mean ΔE*ab 0.15 (LAV/SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body Temperature dependence Spectral reflectance: Within ± 0.10%/°C Color difference: Within ΔE*ab 0.05/°C UV adjustment Instantaneous numerical adjustment UV cut filters 400 nm cutoff and 420 nm cutoff Transmittance chamber Width: 133 mm, Depth: Approx. 50 mm; Measurement diameter: Approx. 17 mm Transmission sample holder (optional accessory): Sample holder; for both plate-shaped and liquid samples (removable) Interface RS-232C, D-sub 9-pin (female) terminal Power AC 100V - 240V 50/60Hz (using included AC adapter) Operating temperature/humidity range 13 - 33°C, relative humidity 80% or less (at 33°C) with no condensation Storage temperature/humidity range 0 - 40°C, relative humidity 80% or less (at 33°C) with no condensation Dimensions (W × H × D) CM-3600d: 244 × 208 × 378 mm CM-3610d: 300 × 597 × 315 mm Weight CM-3600d: 12 kg CM-3610d: 16.5 kg Standard accessories White Calibration Plate, Target Mask (Ø 4 mm), Target Mask (Ø 8 mm), Target Mask (Ø 25.4 mm), Zero Calibration Box, AC Adapter, Dust Cover, Accessory Case, Unit Driver, RS-232C Cable (9-pin, 2 m) Optional accessories Color Data Software PaperControl, NX Color Data Software SpectraMagic(tm) NX, Transmittance Specimen Holder, Glass Cell (2 mm)/(10 mm)/(20 mm), Plastic Cell (2 mm)/(10 mm)/(20 mm), Transmittance Zero Calibration Plate, RS-232C Cable IF-A13 (5 m)   PDF Dosyasını İndir

Konica Minolta Spectrophotometer Bench Top-CM-3630

PDF Dosyasını İndir

Konica Minolta Spectrophotometer Bench Top-CM-3700d

CM-3700d Spectrophotometer (spectral type, side port) Featuring a d:8° optical system (diffused illumination; 8° viewing) compliant with ISO, DIN, and JIS, the CM-3700d provides a wide range of measurement functions and supports many different applications. Specifications Principal Specifications CM-3700d Illuminating/viewing system d:8° (diffused illumination; 8° viewing angle); switchable: di:8° SCI (specular component included) or de:8° SCE (specular component excluded; meets ISO and DIN standards for d:8° geometry; also meets CIE and ASTM standards for d:0° geometry. Transmittance: d:0° (diffuse illumination/0° viewing angle) Detector Silicon photodiode array with flat holographic grating Wavelength range 360 nm to 740 nm Wavelength pitch 10 nm Half bandwidth Approximately 14 nm average Photometric range 0 to 200%; Resolution: 0.001% Light source Pulsed xenon arc lamp Measurement time 0.6 to 0.8 sec. (to start of data output) Illumination/measurement areas Reflectance: Changeable between LAV, MAV, and SAV LAV: Ø 28 mm illumination / Ø 25.4 mm measurement MAV: Ø 11 mm illumination / Ø 8 mm measurement SAV: 5 × 7 mm illumination / 3 × 5 mm measurement Transmittance: Approx. Ø 20 mm Repeatability When white calibration plate is measured 30 times at 10-sec. intervals after white calibration has been performed: ; Spectral reflectance: Standard deviation within 0.05% Chromaticity: Standard deviation within ΔE*ab 0.005 When black tile (BCRA Series II; reflectance: 1%) is measured 30 times at 10-sec. intervals after white calibration has been performed: Spectral reflectance: 380 to 740 nm: Standard deviation within 0.02% 360 and 370 nm: Standard deviation within 0.04% Chromaticity: Standard deviation within ΔE*ab 0.05 Inter-instrument agreement (LAV) Mean ΔE*ab 0.08 (typical) Average for 12 BCRA Series II color tiles. Max ΔE*ab 0.3 (corresponds to ΔECMC 0.2) for any of 12 BCRA Series II color tiles compared to values measured with master body Temperature drift Spectral reflectance: Within ±0.10%/°C Color difference: Within ΔE*ab 0.05/°C UV adjustment Computer controlled; continuously variable Specimen conditions for transmittance measurements Sheet, plate, or liquid form up to a maximum thickness of approximately 50 mm Interface RS-232C standard; baud rates: 1200, 2400, 4800, or 9600 Power AC 100V/120V/230V 50/60Hz (using included AC adapter) Operating temperature/humidity range 13 - 33°C, relative humidity 80% or less with no condensation Storage temperature/humidity range 0 - 40°C, relative humidity 80% or less with no condensation Dimensions (W × H × D) 271 × 259 × 500 mm Weight 18 kg Standard accessories White Calibration Plate; Target Mask (3 × 5 mm); Target Mask (Ø 8 mm); Target Mask (Ø 25.4 mm); Zero Calibration Box; AC Adapter; RS-232C Cable (2 m/6.6 ft., 9-pin, for IBM PC); Accessory Case CM-66 Optional accessories Color Data Software SpectraMagic NX; Transmittance Specimen Holder; Glass Cells (2 mm, 10 mm, 20 mm); Plastic Cells (2 mm, 10 mm, 20 mm); Transmittance Zero Calibration Plate; Color Tiles; RS-232C Cable (for IBM PC)   PDF Dosyasını İndir

Konica Minolta Spectrophotometer Portable-CM-512m3

Specifications Principal Specifications CM-512m3 Illuminating/viewing system 3-angle circumferential illumination (25°, 45°, and 75°)/0° viewing angle Wavelength range 400 to 700 nm Wavelength pitch 20 nm Photometric range 25°: 0 to 300% reflectance; 45°, 75°: 0 to 200% reflectance; Resolution: 0.01% Light source 3 pulsed xenon arc lamps Minimum measurement interval 7 seconds (when measuring a white calibration plate at 23°C) Battery life Alkaline manganese batteries: Approx. 400 measurements at 10 sec. intervals (when dark color is measured) Measurement/illumination area Ø 12 mm / Ø 20 mm Repeatability Spectral reflectance: Standard deviation within 0.30% Colorimetric values: Standard deviation ΔE*ab within 0.05 (Measurement conditions: White calibration plate measured 30 times at 10s intervals) Interface RS-232C Terminal; D-sub 9-pin (female) Display Dot-matrix reflective LCD with 21 characters ×7 lines (128 × 56 dots) With contrast control slide Display data Colorimetric data: L*a*b*, L*C*h Color difference data: Δ(L*a*b*), Δ(L*C*H*), ΔE*ab, CMC(l:c), ΔE00(CIE DE2000) Other data display: FF value, line graph, temperature Observer condition CIE: 2° and 10° standard observer     Illuminant condition CIE: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) Temperature detection Detector: Thermopile Wavelength: 8 to 13 µm Measurement/display range: -10 to 80°C (0.1°C increments) Measurement diameter: Ø 20 mm Measurement rating: 0 to 50°C: ±2.5°C ±1 digit (when an object of 0.93 emissivity is measured at ambient temperatures of 18 to 28°C) Operating temperature/humidity range 0 - 40°C; relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 - 45°C; relative humidity 85% or less (at 35°C) with no condensation Power Four AA-size batteries or AC adapter AC-A308 Dimensions (W × H × D) 115 × 257 × 164 mm Weight Approx. 1.4 kg (without batteries) Standard accessories Hard case, White calibration plate, RS-232C cable, AC adapter, AA-size battery (×4) Optional Accessories Grip CM-A42, SpectraMagic(tm)NX (software)   PDF Dosyasını İndir

Konica Minolta Spectrophotometer Portable-CM-700d & 600d

Specifications Principal Specifications CM-700d / 600d Model CM-700d CM-600d Illumination/viewing system di:8°, de:8°  (diffused illumination, 8-degree viewing angle), d:8° (diffuse illumination/8° viewing angle), selectable SCI (di:8° specular component included) and/or SCE (de:8° specular component excluded) measurement. Conforms to CIE No. 15, ISO 7724/1, ASTM E-1164, DIN 5033 Teil 7, and JIS Z8722 Condition C standards. Size of integrating sphere Ø 40 mm Detector Silicon photodiode array (dual 36-element) Spectral separation device Diffraction grating Wavelength range 400 nm to 700 nm Wavelength pitch 10 nm Half bandwidth Approx. 10 nm Light source Pulsed xenon lamp (with UV cut filter) Measurement time Approx. 1 second Battery performance With alkaline dry batteries: Approx. 2000 measurements With nickel-metal-hydride rechargeable batteries (2300 mAh): Approx. 2000 measurements with full charge * Measured at 10-second intervals at 23°C; measurement fixed at SCI or SCE Measurement/illumination area MAV: Ø 8 mm / Ø 11 mm SAV: Ø 3 mm / Ø 6 mm *Changeable by replacing target mask and selecting lens position MAV: Ø 8 mm / Ø11 mm only Repeatability Spectral reflectance: Standard deviation within 0.1%, Chromaticity value: Standard deviation within ΔE *ab 0.04* When a white calibration plate is measured 30 times at 10-second intervals after white calibration Inter-instrument agreement Within ΔE*ab 0.2 (MAV/SCI) * Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C Display 2.36-inch TFT color LCD Interfaces USB1.1; Bluetooth(r) standard version 1.2* Observer condition CIE: 2° and 10° standard observer Illuminant condition CIE: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) Displayed data Spectral values/graph, colorimetric values, color difference values/graph, PASS/FAIL result, color patch, color assessment Color spaces L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color difference in these spaces (except for Munsell) Colorimetric data MI, WI (ASTM E313), YI (ASTM E313-73/ASTM D1925), ISO Brightness, 8° gloss value Color difference formulas ΔE*ab (CIE1976), ΔE*94 (CIE1994), ΔE00 (CIE 2000), CMC (l:c) Storable data sets Measurement data: 4000 sets/Target color difference data: 1000 sets Power 4 AA-size alkaline dry batteries or nickel-metal-hydride rechargeable batteries; , Special AC adapter Dimensions (W x H x D) 73 x 211.5 x 107 mm Weight Approx. 550 g (without white calibration cap and batteries) Operating temperature/ humidity range 5 to 35°C; relative humidity 80% or less with no condensation Storage temperature/ humidity range 0 to 45°C; relative humidity 80% or less with no condensation PDF Dosyasını İndir

Konica Minolta Spectrophotometer Portable-CM-2500c

Specifications Principal Specifications CM-2500c Model Spectrophotometer CM-2500c Illumination/viewing system 45°a:0° method (45° annular illumination, 0° vertical viewing) Light-receiving element Silicon photodiode array (dual 40 elements) Spectral separation device Diffraction grating Wavelength range 360 nm to 740 nm Wavelength pitch 10 nm Half bandwidth Approx. 10 nm Reflectance range 0 to 175%, resolution: 0.01% Light source 2 pulsed xenon lamps Measurement time Approx. 1.5 seconds Minimum interval between measurements 4 seconds Battery performance Alkaline manganese: Approx. 1000 measurements, (at 23°C) Measurement/illumination area Ø 7 mm / Ø 11 mm Repeatability Colorimetric Value: Standard deviation within ΔE*ab 0.05 (Measurement conditions: White calibration plate measured 30 times at 10-second intervals after white calibration was performed) Inter instrument agreement Within ΔE*ab 0.25 (Average for 12 BCRA Series II color tiles compared to values measured with master body; at 23°C) Measurement mode Single measurement/automatic averaging of multiple measurements (auto mode: 3, 5, 8 times/manual mode) Interface RS-232C standard Observer condition CIE: 2° and 10° standard observer Illuminant condition CIE: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) Display data Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result, ASSESSMENTS (Except for Japanese mode) Color space/colorimetric data L*a*b*, L*C*h, CMC(1:1), CMC(2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ, MI, WI (ASTM E313), WI (CIE), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density status A/T, WI/Tint (CIE), CIE 00 Data memory 700 Pass/Fail judgment Tolerance for color difference (Both box and elliptical tolerances can be set) Power source 4 AA-size batteries or AC adapter Dimensions (W × H × D) 69 × 96 × 193 mm Weight Approx. 670 g (without batteries) Operating temperature/humidity range 5 - 40°C, relative humidity 80% or less (at 35°C) with no condensation Storage temperature/humidity range 0 - 45°C, relative humidity 80% or less (at 35°C) with no condensation Standard accessories White calibration plate, RS-232C cable, AC adapter, AA-size battery (×4) Optional Accessories Hard case, Dust cover set, Dust cover, SpectraMagic(tm)NX (software), Zero calibration box. PDF Dosyasını İndir

Konica Minolta Spectrophotometer Portable-CM-2600d_2500d

Specifications Principal Specifications CM-2600d Model CM-2600d CM-2500d Illumination / Viewing system d:8° (diffuse illumination, 8-degree viewing ), equipped with simultaneous measurement of SCI (di:8° specular component included) / SCE (de:8° specular component excluded) Conforms to CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7 and JIS Z8722 Condition C standard. Sphere Size Ø 52 mm Light-receiving element Silicon photodiode array (dual 40 elements) Spectral separation device Diffraction grating Wavelength range 360 nm to 740 nm Wavelength pitch 10 nm Half bandwidth Approx. 10 nm Reflectance range 0 to 175%, resolution: 0.01% Light source 3 pulsed xenon lamps 2 pulsed xenon lamps Measurement time Approx. 1.5 seconds (approx. 2 seconds for fluorescent measurement) Approx. 1.5 seconds Minim um interval between measurements 3 seconds for SCI/SCE (4 seconds for fluorescent measurement) 3 seconds for SCI/SCE Battery perfomance Alkaline manganese:approx. 1000 measurements Measurement/illumination area MAV : Ø 8 mm / Ø 11 mm SAV : Ø 3mm / Ø 6 mm (Selectable between MAV and SAV) MAV : Ø 8 mm / Ø 11 mm Repeatability Spectral Reflectance:Standard deviation within 0.1% (360 to 380 nm within 0.2%) Colorimetric Value : Standard deviation within ΔE*ab 0.04 (Measurement conditions:White calibration plate measured 30 times at 10-second intervals after white calibration was performed) Inter instrument agreement withinΔE*ab 0.2 (MAV/SCI) Average for 12BCRA Series II color tiles compared to values measured with master body. UV adjustment Instantaneous numerical adjustment (no mechanical adjustment required) With UV400nm cut filter No UV adjustment Measurement mode Single measurement/automatic averaging of multiple measurements(auto mode: 3, 5, 8 times/manual mode) Interface RS-232C standard Observer condition CIE: 2° and 10° standard observer Illuminant condition CIE: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) Display data Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result Color space / colorimetric data L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density statusA /T, WI/Tint (CIE/Ganz), CIE00 Data memory 1700 sets of data (as SCI/SCE 1 data) * 700 sets of data in the "defined in COND." mode. * Total of the sample data for the COND and TASK modes and color diference target data Tolerance judgment Tolerance for color difference (both box and eliptical tolerances can be set) Power source 4 AA-size battery or AC adapter AC-A305 Dimensions (W × H × D) 69 × 96 × 193 mm Weight Approx. 670 g (without batteries) Operating temperature / humidity range (*1) 5 - 40°C, relative humidity 80% or less (at 35°C) with no condensation Storage temperature/humidity range 0 - 45°C, relative humidity 80% or (at 35°C) with no condensation Standard accessories White calibration plate, Target mask Ø 8 mm, Target mask Ø 3 mm , RS-232C cable, AC adapter,AA-size battery (×4) Optional Accessories Hard case, Dust cover set, Dust cover, SpectraMagic(tm)NX (software), Zero calibration box.   PDF Dosyasını İndir

Mettler Industrial Weighing-Floor Pit Scale M-Line

The assortment of floor/pit scales of the M-line includes weighing ranges from 600 to 3000 kg with a verificable resolution of 3x3000 e (multi-interval). The weighing platform sizes vary from 1250x1000 mm to 1500x1500 mm. The hybrid construction - strain gauge measuring cell and lever arm system - guarantees best linearity with slight corner load tolerances. The individual models are available as stainless steel- or hot galvanized version and can be used in wet or dry areas. All models are approved for operation in hazardous areas of zone 2 / 22. Digital measuring cell The weighing cell, consisting of strain gauge sensor and integrated A/D-converter, provides precise weighing results.  Plug'n weigh The digital measuring cell allows an easy and problem-free connection of all ID-operating terminals in verificable mode.  Three scales in one Thanks to the multi-interval-function, one can always weigh with the optimal resolution. Update rate of 10 ups High efficiency for dispensing and filling IP-protection The measuring cell has an IP67-protection and is safeguarded against penetration of water and dust. Type of protection The measuring cell has the following type of protection: II 3 G EEx nA IIC T6, II 3 D IP67 T50° C. Products   Maximum Capacity Readability DRF3000 3000.0 kg 200 g DRF3000sx 3000.0 kg 200 g DRF6000 6000.0 kg 500 g DRF6000sx 6000.0 kg 500 g DSF12000 12000.0 kg 1000 g DSF12000sx 12000.0 kg 1000 g DSF3000 3000.0 kg 200 g DSF3000sx 3000.0 kg 200 g DSF6000 6000.0 kg 500 g DSF6000sx 6000.0 kg 500 g MC300 60 kg / 150 kg / 300.0 kg 10 g MC300s 60 kg / 150 kg / 300.0 kg 10 g MC600 150 kg / 300 kg / 600.0 kg 20 g MC600s 150 kg / 300 kg / 600.0 kg 20 g MCS300 60 kg / 150 kg / 300.0 kg 10 g MCS300s 60 kg / 150 kg / 300.0 kg 10 g MCS600 150 kg / 300 kg / 600.0 kg 20 g MCS600s 150 kg / 300 kg / 600.0 kg 20 g MD1500 300 kg / 600 kg / 1500.0 kg 50 g MD600 150 kg / 300 kg / 600.0 kg 20 g ME1500 300 kg / 600 kg / 1500.0 kg 50 g ME1500sk 300 kg / 600 kg / 1500.0 kg 50 g ME3000 600 kg / 1500 kg / 3000.0 kg 10 g ME3000sk 600 kg / 1500 kg / 3000.0 kg 10 g MES1500, MES1500sk 300 kg / 600 kg / 1500.0 kg 50 g MES3000, MES3000sk 600 kg / 1500 kg / 3000.0 kg 10 g