ATAGO

Multi-wavelength Abbe Refractometers

Multi-Wavelength Abbe Refractometer DR-M2

Refractive index or Abbe number (νd or νe) can be measured at different wavelengths ranging from 450 to 1,100nm. The DR-M2 digitally displays measurement result of refractive index or Abbe number on the LCD. Measurement can be achieved by matching the boundary line with the intersection point of the cross hairs. This refractometer is connectable with Digital printer DP-63(B) (Optional). Specifications ModelDR-M2 Cat.No.1410 ScaleRefractive index Abbe number Measurement RangeRefractive index 1.3278 to 1.7379 (Wavelength 450nm) Refractive index 1.3000 to 1.7100 (Wavelength 589nm) Refractive index 1.2912 to 1.7011 (Wavelength 680nm) Refractive index 1.2743 to 1.6840 (Wavelength 1,100nm) Minimum IndicationRefractive index : 0.0001 Abbe number : 0.1 Measurement AccuracyRefractive index : ±0.0002 (With the attached test piece at 500 to 650nm) Ambient Temperature5 to 40゚C Measurement Temperature Range5 to 50゚C (With circulating constant water bath) Display PanelLCD Light sourceHalogen lamp OutputFor printer, DP-63 (B) (Optional) Wavelength RangeFrom 450 to 1100nm (with interference filters) (For measurement at wavelengths ranging from 681 to 1100nm, the Near Infrared Ray Viewer (Optional is required) Power SupplyAC100 to 240V, 50/60Hz Dimensions & Weight13×29×31cm, 6.0kg (Refractometer) 15×33×11cm, 3.2kg (Light source unit) Power consumption160VA

Multi-Wavelength Abbe Refractometer DR-M4

Refractive index or Abbe number (νd or νe) can be measured at different wavelengths ranging from 450 to 1,100nm (For measurement at wavelengths ranging from 681 to 1,100nm, the Optional Near Infrared Ray Viewer (RE-9119) is required. The DR-M4 displays measurement result of refractive index or Abbe number digitally on the LCD. Measurement can be achieved by matching the boundary line with the intersection point of the cross hairs. This refractometer is connectable with Digital printer DP-63 (B)(Optional) . Specifications ModelDR-M4 Cat.No.1414 ScaleRefractive index Abbe number Measurement RangeRefractive index : 1.5219 to 1.9220 (at 450nm) Refractive index : 1.4700 to 1.8700 (at 589nm) Refractive index : 1.4545 to 1.8544 (at 680nm) Refractive index : 1.4260 to 1.8259 (at 1,100nm) Minimum IndicationRefractive index : 0.0001 Abbe number : 0.1 Measurement AccuracyRefractive index : ±0.0002 (With the attached test piece at 500 to 650nm) Ambient Temperature5 to 40゚C Measurement Temperature Range5 to 50゚C Display PanelLCD Light sourceHalogen lamp, 12V 50W OutputFor printer, DP-63 (B) (Optional) Wavelength RangeFrom 450 to 1100nm (with interference filters) (For measurement at wavelengths ranging from 681 to 1100nm, the Near Infrared Ray Viewer (Optional is required) Power SupplyAC100 to 240V, 50/60Hz Dimensions & Weight13×29×31cm, 6.0kg (Refractometer) 15×33×11cm, 3.2kg (Light source unit) Power consumption160VA

Multi-Wavelength Abbe Refractometer DR-M2/1550

Refractive index or Abbe number (νd or νe) can be measured at different wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD. This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with Digital printer DP-63 (B) (Optional). Specifications ModelDR-M2/1550 Cat.No.1412 ScaleRefractive index Abbe number Measurement RangeRefractive index : 1.3278 to 1.7379 (at 450nm) Refractive index : 1.3000 to 1.7100 (at 589nm) Refractive index : 1.2912 to 1.7011 (at 680nm) Refractive index : 1.2743 to 1.6840 (at 1,100nm) Refractive index : 1.2662 to 1.6759 (at 1,550nm) Minimum IndicationRefractive index : 0.0001 Abbe number : 0.1 Measurement AccuracyRefractive index : ±0.0002 (With the attached test piece at 589nm) Ambient Temperature5 to 40゚C Measurement Temperature Range5 to 50°C (Temperature range available of the circulating water) Display PanelLCD Light sourceMonochromatic light source device Dimensions & Weight : 22×30×20 to 30cm, 5.2kg Power consumption : 240VA OutputFor printer, DP-63 (B)(Optional) Wavelength RangeFrom 450 to 1,550nm (With interference filters) Main ComponentsRefractometer, Power supply unit, Monochromatic light source device, Near infrared ray viewer, Interference filter (589nm). Power SupplyAC100 to 240V, 50/60Hz Dimensions & Weight13×29×31cm, 6.0kg (Refractometer) 15×33×11cm, 3.2kg (Power supply unit) Power consumption160VA (Refractometer, Power supply unit)

Multi-Wavelength Abbe Refractometer DR-M4/1550

Refractive index or Abbe number (νd or νe) can be measured atdifferent wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD. This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with Digital printer DP-63(B) (Optional). Specifications ModelDR-M4/1550 Cat.No.1415 ScaleRefractive index Abbe number Measurement RangeRefractive index : 1.5219 to 1.9155 (at 450nm) Refractive index : 1.4700 to 1.8700 (at 589nm) Refractive index : 1.4561 to 1.8544 (at 680nm) Refractive index : 1.4310 to 1.8259 (at 1,100nm) Refractive index : 1.4215 to 1.8136 (at 1,550nm) Minimum IndicationRefractive index : 0.0001 Abbe number : 0.1 Measurement AccuracyRefractive index : ±0.0002 (With the attached test piece at 589nm) Ambient Temperature5 to 40゚C Measurement Temperature Range5 to 50゚C Display PanelLCD Light sourceMonochromatic light source device Dimensions & Weight : 22×30×20 to 30cm, 5.2kg Power Consumption : 240VA OutputFor printer, DP-63 (B) (Optional) Wavelength RangeFrom 450 to 1,550nm (With interference filters) Main ComponentsRefractometer, Power supply unit, Monochromatic light source device, Near infrared ray viewer, Interference filter (589nm) . Power SupplyAC100 to 240V 50/60Hz Dimensions & Weight13×29×31cm, 6.0kg (Refractometer) 15×33×11cm, 3.2kg (Power supply unit) Power consumption160VA(Refractometer, Power supply unit)

Circulating Constant Temperature Bath 60-C4

The 60-C4 is an external circulation type constant temperature water tank provided with a thermo-module. The temperature can be set in the range of 10 to 60°C and the unit is perfectly suited for connection with a refractometer. Specifications Model60-C4 Cat.No.1922 Tank Capacity0.5 lit Temperature Setting Range10 to 60°C (water) Temperature controlPID control method using a thermo-module Power SupplyAC 100 to 240V, 50/60Hz Constant-Temperature Accuracy±0.2°C Dimensions & Weight38×24×27cm, 11.0kg (Main Unit only) Power consumption430VA Flow Rate4 lit / min