Thermo Scientific Alpha pH 2000D Wall Mount Differential pH/ORP Controller/Transmitter

Product Features The Alpha pH 2000D Controller/Transmitter and combination electrode system employs differential pH measurement technology. What’s unique about this system is the differential electrode, which uses a pH glass bulb in place of the conventional reference system, making it more resistant to contamination or fouling in harsh wastewater applications. Replaceable salt bridge and reference solution add lifespan to the electrode when junction clogs. The result: a reliable, long-lasting and cost-saving pH measurement system for demanding environments. ::Wide pH range of -2.00 to 16.00 pH at two-decimal accuracy ::ORP mode measures in mV or % concentration, with independent calibration modes ::Control and measure pH and ORP simultaneously with master-slave operation by placing two controllers side by side ::Wall mount, pipe mount or panel mount options. Compact design of electrode with universal 1.5” NPT mounting threads enables optimal mounting positions The pH Differential Electrode: ::Cost Savings, Reduced Downtime and Maintenance Costs – soiled salt bridge and buffer reference solution can easily be replaced at a fraction of the cost of a new combination electrode ::Automatic Temperature Compensation – built-in temperature electrode ::Use Any Buffer Standard from 2 to 10 pH as a Reference – very useful for applications that require adjustable isopotential points ::Built-In Electronic Amplifier provides a low impedance output from the electrode, and allows analyzers to be located up to 3000 feet away from the electrode ::Ground Rod Minimizes Electrical Interference from motors, pumps, transformers and ground currents Applications General: Useful for any batch or on-line type application that requires accurate pH or ORP control. Water Purification/Treatment: Use for batch and on-line control of incoming process water, rinse water treatment, recirculating system and waste water treatment. Industrial: Ideal for chemical processing, food processing. aquarium, pharmaceutical, hydroponics and waste control industries. Regulatory: Hook to recorder to document data for regulatory compliance.

Thermo Scientific Alpha pH 2000 Wall Mount/Panel Mount pH/ORP Controller/Transmitter

Product Features Built for the rugged industrial environment, the Alpha pH 2000 transmitter comes with an option for symmetrical mode of operation, making it ideal for electrically noisy environments. IP65 NEMA 4X casing is weatherproof and corrosion-resistant, protecting meter against harsh elements. The Alpha pH 2000 is user-friendly and intuitive: controller alerts when meter or electrode requires maintenance, and provides trouble-shooting prompts in plain language. ::Wide pH range of -2.00 to 16.00 pH at two-decimal accuracy ::ORP mode measures in mV or % concentration, with independent calibration modes ::Quick, easy push-button calibration with auto-buffer recognition. Meter displays electrode status after each calibration ::Accepts Antimony electrodes – useful in applications involving Hydrofluoric (HF) Acid ::Control and measure pH and ORP simultaneously with master-slave operation by placing two controllers side by side Asymmetrical Asymmetrical mode works well in environments with where there is little or no electrical noise. When there is electrical noise, the noise acts as a common signal and is picked up by both the pH and the reference electrodes. However, since the reference electrode is grounded to the ground potential of the amplifier, electrical noise will be present only on the pH electrode. This noise is amplified along with the pH signal, which causes reading fluctuations in an electrically noisy atmosphere. Electrical noise from a DC source (as in an electroplating tank) will typically result in stable but incorrect values. Symmetrical Symmetrical mode avoids grounding the reference electrode by reconfiguring the input to a floating differential mode. The electrical noise appears equally on the pH and reference electrodes, and is therefore rejected by the operational amplifier. The Alpha pH 2000 transmitter offers an option for Symmetrical Mode of Operation. To take advantage of Symmetrical operation, you must have an electrode with a solution ground (potential matching) pin. If your electrode does not have a solution ground, be sure to set the controller to Asymmetrical mode. Applications General: Useful for any batch or on-line type application that requires accurate pH or ORP control. Water Purification/Treatment: Use for batch and on-line control of incoming process water, rinse water treatment, recirculating system and waste water treatment. Industrial: Ideal for chemical processing, food processing. aquarium, pharmaceutical, hydroponics and waste control industries. Regulatory: Hook to recorder to document data for regulatory compliance.

Thermo Scientific Alpha COND 2000 Wall Mount/Panel Mount Conductivity Controller/Transmitter

Product Features Measure from ultra-pure water to highly conductive samples with the Alpha COND 2000 controller/transmitter: this conductivity controller accepts 4-cell and 2-cell electrodes, and features programmable temperature coefficients to give you precise temperature compensation. ::Measures seven ranges, from 0 to 2 µS/cm to 0 to 1000 mS/cm ::Readings of up to three-decimal resolution at ±1 % accuracy ::Adjustable temperature coefficients for more precise temperature compensation: Choose between programmable linear temperature compensation from 0.0 % to 10.0 %, and pure water temperature compensation to correct non-linearity of ultrapure water temperature correction curves ::Meter displays electrode status after each calibration ::User-adjustable cell constant values (k = 0.005 to k = 9.999) ::4-cell electrode prevents polarizing effects and electrode fouling in samples with high conductivity ::Accepts 2- or 3-wire, Pt100 or Pt1000 RTD sensors for automatic temperature compensation ::Allows user to input cell constant corresponding to connecting electrode independently during calibration Applications General: Use for virtually any batch or online applications where rapid, accurate control. Great for OEM/system integrator. Industrial: Use in applications involving agriculture, chemical processing, boiler and water heaters, wafer-fab, microprocessor manufacturing, pharmaceuticals, pulp and paper industries, and bleach manufacturing. Water Purification/Treatment: Use to treat batches of incoming process water, ultrapure water, boiler and feed water control. Regulatory: Hook to recorder to document data for regulatory compliance.

Thermo Scientific Alpha DO 2000 Dissolved Oxygen Controller/Transmitter

Product Features With a wide measuring range of 0 to 20 ppm or 0 to 200 % saturation, Alpha DO 2000 controller/transmitter is ideal for use in a variety of applications, ranging from water treatment and monitoring to pharmaceutical and food processing. Meter comes in both Galvanic and Amperometric versions. ::Readings values in mg/L or % air saturations, selectable from menu options ::Quick, easy calibration using atmospheric air as calibration media for 100 % air saturation ::Pressure, Salinity and Automatic Temperature Compensation The Galvanic Electrode (ECDOGEN-S & ECDOTPII-S) Rugged and long-lasting, the galvanic electrode requires no warm-up time and prevents zero drift by recreating H2O within the electrode. This prevents change of pH to the electrode and allows it to recycle within the probe. The result: galvanic sensors have long lifespans and require low maintenance costs. The Amperometric Electrode (EC237150 & EC237450) The amperometric dissolved oxygen electrode contains special membranes that are designed to require almost zero maintenance. These unique membranes stay stable even under harsh ambient conditions and high pressure. This enables the sensors to capture accurate DO readings within short response time at required flow as low as 0.02 m/s. Applications General: Useful for monitoring temperature and control of DO in wastewater treatment and aquaculture applications. Use with valves, blowers or aerators to ensure proper system operation.

Thermo Scientific Alpha pH 1000 pH/ORP Controller/Transmitter

Product Features The Alpha pH 1000 controllers/transmitters combines consistent performance and sophisticated control functions with user-friendly features. Meters come with seven preset buffer values for quick, accurate auto-calibration; electrode offset function allows direct reading corrections without needing to remove electrode from the control system. Alarm delay and individual set-point hystereses in limit control mode prevent chattering, false alarms, and uncecessary down time. For finer control, Alpha pH 1000 offers proportional pulse length control and proportional pulse frequency control, in addition to basic limit control. ::2-in-1 controllers/transmitters can be configured to measure either pH or OPR (mV or %) ::Auto-calibration with choice of NIST or USA buffer selection. Electrode slope and offset is displayed after each successful calibration ::Symmetrical mode option for clear, uninterrupted pH readings in electronically noisy environment ::Antimony mode option for use with antimony electrodes in applications that involves corrosive Hydrofluoric Acid ::Option of Auto or Manual Temperature Compensation. Three-wire system compensates for cable-length resistance errors ::Galvanically-isolated, scaleable 0/4 to 20 mA output for high-quality output on peripheral devices ::Alpha pH 1000 limit/proportional controller also offer two additional features: wash function for scheduled electrode wash, and alarm relay function to alert when measurement crosses the set points Applications General: Useful for any batch or on-line type application that requires accurate pH or ORP control. Water Purification/Treatment: Use for batch and on-line control of incoming process water, rinse water treatment, recirculating system and waste water treatment. Industrial: Ideal for chemical processing, food processing. aquarium, pharmaceutical, hydroponics and waste control industries. Regulatory: Hook to recorder to document data for regulatory compliance.

Thermo Scientific Alpha COND 1000 Conductivity Controller/Transmitter

Product Features The Alpha COND 1000 features up to ten selectable conductivity ranges and corresponding cell constant K values, easily configured through a six-button keypad. Adjustable temperature co-efficient and ultrapure water compensation option allow measurements in broad-range applications, from ultrapure water to high-conductivity samples. ::±1% full scale accuracy across ten different Conductivity ranges ::Adjustable temperature coefficient from 0.0 to 10.0% for higher accuracy ::Pure water compensation option corrects non-linearity of pure water temperature correction curves in ultrapure water applications ::Option of Auto or Manual Temperature Compensation. Three-wire system compensates for cable-length resistance errors ::Meter displays electrode information after each successful calibration. Previous calibration data is retained in the event of unsuccessful calibrations ::Line adjustment feature corrects long cable resistance errors – an important feature useful in applications involving high conductivity measurements ::Galvanically-isolated, scaleable 0/4 to 20 mA output for high-quality output on peripheral devices Applications General: Use for virtually any batch or online applications where rapid, accurate control. Great for OEM/system integrator. Industrial: Use in applications involving agriculture, chemical processing, boiler and water heaters, wafer-fab, microprocessor manufacturing, pharmaceuticals, pulp and paper industries, and bleach manufacturing. Water Purification/Treatment: Use to treat batches of incoming process water, ultrapure water, boiler and feed water control. Regulatory: Hook up to recorder for regulatory compliance data collection.

Thermo Scientific Alpha DO 1000 Dissolved Oxygen Controller/Transmitter

Product Features The Alpha DO 1000 controller/transmitter accepts low-range and general range probe for extensive measurement range of Dissolved Oxygen in ppm, mg/L or % saturation. Versatile controller/transmitter offers three Dissolved Oxygen control mode: limit control, proportional pulse length control and proportional pulse frequency control. ::Accepts low range probes (0 to 10 ppm) and general range probes (0.5 to 40 ppm) ::Allows one point or two point DO calibration. Meter displays electrode information after each successful calibration. Previous calibration data is retained in the event unsuccessful calibration ::Automatic salinity and pressure compensation after manual input for more accuracte readings ::Option of Auto or Manual Temperature Compensation. Three-wire system compensates for cable-length resistance errors ::Galvanically-isolated, scaleable 0/4 to 20 mA output for high-quality output on peripheral devices Applications General: Useful for monitoring temperature and control of DO in wastewater treatment and aquaculture applications. Use with valves, blowers or aerators to ensure proper system operation.

Thermo Scientific Alpha RES 1000 Resistivity Controller/Transmitter

Product Features The Alpha RES 1000 offers high accuracy across 2 resistivity ranges with adjustable temperature co-efficient and pure water compensation option. Controller/ transmitter is equipped with alarm delay and individual set-point hystereses to prevent chattering, false alarms, and uncecessary down time. ::±1% full scale accuracy across two Resistivity ranges ::Adjustable temperature coefficient from 0.0 to 10.0 % for higher accuracy ::Pure water compensation option corrects non-linearity of pure water temperature correction curves in ultrapure water applications ::Option of Auto or Manual Temperature Compensation. Three-wire system compensates for cable-length resistance errors ::Meter displays electrode information after each successful calibration. Previous calibration data is retained in the event of unsuccessful calibrations ::Galvanically-isolated, scaleable 0/4 to 20 mA output for high-quality output on peripheral devices Applications General: Use for virtually any batch or online applications where rapid, accurate control. Great for OEM/system integrator. Water Purification/Treatment: Suitable for pure, ultrapure, and reagent grade water batches of incoming process water. Regulatory: Hook to recorder to document data for regulatory compliance.

Thermo Scientific Alpha pH 800 pH/ORP Controllers/Transmitters

Product Features The Alpha pH 800 controllers/transmitters combines consistent performance and sophisticated control functions with user-friendly features. Meters come with seven preset buffer values for quick, accurate auto-calibration; electrode offset function allows direct reading corrections without needing to remove electrode from the control system. Alarm delay and individual set-point hystereses in limit control mode prevent chattering, false alarms, and uncecessary down time. ::2-in-1 controllers/transmitters can be configured to measure either pH or OPR (mV or %) ::Auto-calibration with choice of NIST or USA buffer selection. Electrode slope and offset is displayed after each successful calibration ::Symmetrical mode option for clear, uninterrupted pH readings in electronically noisy environment ::Antimony mode option for use with antimony electrodes in applications that involves corrosive Hydrofluoric Acid ::Option of Auto or Manual Temperature Compensation. Three-wire system compensates for cable-length resistance errors ::Galvanically-isolated, scaleable 0/4 to 20 mA output for high-quality output on peripheral devices Applications General: Useful for any batch or on-line type application that requires accurate pH or ORP control. Water Purification/Treatment: Use for batch and on-line control of incoming process water, rinse water treatment, recirculating system and waste water treatment. Industrial: Ideal for chemical processing, food processing. aquarium, pharmaceutical, hydroponics and waste control industries.

Thermo Scientific Alpha pH 190 pH/ORP Controller/Transmitter

Product Features pH/ORP control is easy with the Alpha pH 190 limit controllers. Featuring 6 sub-menus accessible via a four-button keypad for quick, easy setup and calibration, the controller/transmitters also come with two levels of password to protect against unauthorised tampering. For faster and more convenient control, choose the Alpha pH 190 which allows direct access to the set-point adjustment and calibration menus. ::Easy push-button calibration with USA/NIST buffer recognition for fast, effortless calibration. Controller freezes data transmission and relay activities during calibration and maintenance ::Symmetrical mode of operation for clear, uninterrupted readings even in electronically noisy environments ::Two SPDT relays with independent hysteresis – effective high/low set-points limit control with minimal relay-chattering ::Choice of automatic or manual temperature compensation. Three-wire system compensates error due to cable resistance ::85 to 250 VAC. 50/60 Hz or DC variable input allows controller to be used with a wide range of supply voltages ::Full-scale 4 to 20 mA galvanically isolated current output for process control Applications General: Ideal for virtually any batch type application where pH or ORP control or adjustment is needed. Use as ORP monitor for ozone systems and general purpose pH monitor for all types of water treatment and chemical processes. Aquaculture: Use for pH or ORP control in fish ponds and tanks. Industrial: Use to treat batches of incoming process water, rinse water treatment, recirculating system and wastewater treatment. Suitable for pH or ORP control of plating tanks and chemical processing tanks. Ideal for low cost monitor with alarms for batch and process applications. Perfect for wastewater neutralization in small and medium sized batches.

Thermo Scientific Alpha COND 190 Conductivity Controller/Transmitter

Product Features Measure from pure water to electroplating rinse tank water with Thermo Scientific’s Alpha COND 190. Reliable with straightforward process control, these control/transmitters measures with up to ±1 % full scale accuracy across eight conductivity ranges. For faster and more convenient control, choose the Alpha COND 190 which allow direct access to the set-point adjustment and calibration menus. ::Measures up to eight ranges at ±1 % full range accuracy ::Easy push-button calibration. Controller freezes data transmission and relay activities during calibration and maintenance ::Selectable temperature coefficient for higher Conductivity accuracy ::Two SPDT relays allows high/low set-points limit control. Each relay comes with their independent hysteresis to prevent relay-chattering ::Choice of automatic or manual temperature compensation. Three-wire system compensates error due to cable resistance ::Full-scale 4 to 20 mA galvanically isolated current output for process control ::85 to 250 VAC. 50/60 Hz or DC variable input allows controller to be used with a wide range of supply voltages Applications COND 190: Use for plating tank, rinse water, boiler and cooling tower, feed water and blowdown control, font solution make-up and control for printing, photographic developing, chemical production process, ion exchange systems, R.O. systems, industrial process water, wastewater, dilute acids, salts and bases.

Thermo Scientific Alpha TDS 190 Total Dissolved Solids Controller/Transmitter

Product Features Measure from pure water to electroplating rinse tank water with Thermo Scientific’s Alpha TDS 190. Reliable with straightforward process control, these control/transmitters measures with up to ±1 % full scale accuracy across eight TDS ranges. For faster and more convenient control, choose the Alpha TDS 190 which allow direct access to the set-point adjustment and calibration menus. ::Measures up to eight ranges at ±1 % full range accuracy ::Easy push-button calibration. Controller freezes data transmission and relay activities during calibration and maintenance ::Selectable temperature coefficient for higher TDS accuracy ::Two SPDT relays allows high/low set-points limit control. Each relay comes with their independent hysteresis to prevent relay-chattering ::Choice of automatic or manual temperature compensation. Three-wire system compensates error due to cable resistance ::Full-scale 4 to 20 mA galvanically isolated current output for process control ::85 to 250 VAC. 50/60 Hz or DC variable input allows controller to be used with a wide range of supply voltages Applications TDS 190: Ideal for drinking water, monitoring and control, hydroponics and aquaponic solution balance and control, pools and spa hardness and salinity control.

Thermo Scientific Alpha pH 200 pH/ORP Controller/Transmitter

Product Features pH/ORP control is easy with the Alpha pH 200 limit controllers. Featuring 6 sub-menus accessible via a four-button keypad for quick, easy setup and calibration, the controller/transmitters also come with two levels of password to protect against unauthorised tampering. For heightened security, use the Alpha pH 200 limit controller which only allows access to calibration and set-up menus via passwords. ::Easy push-button calibration with USA/NIST buffer recognition for fast, effortless calibration. Controller freezes data transmission and relay activities during calibration and maintenance ::Symmetrical mode of operation for clear, uninterrupted readings even in electronically noisy environments ::Two SPDT relays with independent hysteresis – effective high/low set-points limit control with minimal relay-chattering ::Choice of automatic or manual temperature compensation. Three-wire system compensates error due to cable resistance ::85 to 250 VAC. 50/60 Hz or DC variable input allows controller to be used with a wide range of supply voltages ::Full-scale 4 to 20 mA galvanically isolated current output for process control Applications General: Ideal for virtually any batch type application where pH or ORP control or adjustment is needed. Use as ORP monitor for ozone systems and general purpose pH monitor for all types of water treatment and chemical processes. Aquaculture: Use for pH or ORP control in fish ponds and tanks. Industrial: Use to treat batches of incoming process water, rinse water treatment, recirculating system and wastewater treatment. Suitable for pH or ORP control of plating tanks and chemical processing tanks. Ideal for low cost monitor with alarms for batch and process applications. Perfect for wastewater neutralization in small and medium sized batches.

Thermo Scientific Alpha COND 200 Conductivity Controllers/Transmitter

Product Features Measure from pure water to electroplating rinse tank water with Thermo Scientific’s Alpha COND 200. Reliable with straightforward process control, these control/transmitters measures with up to ±1 % full scale accuracy across eight conductivity ranges. For heightened security, use the Alpha COND 200 with two levels of password security to protect calibration and meter settings from unauthorised tampering. ::Measures up to eight ranges at ±1 % full range accuracy ::Easy push-button calibration. Controller freezes data transmission and relay activities during calibration and maintenance ::Selectable temperature coefficient for higher Conductivity accuracy ::Two SPDT relays allows high/low set-points limit control. Each relay comes with their independent hysteresis to prevent relay-chattering ::Choice of automatic or manual temperature compensation. Three-wire system compensates error due to cable resistance ::Full-scale 4 to 20 mA galvanically isolated current output for process control ::85 to 250 VAC. 50/60 Hz or DC variable input allows controller to be used with a wide range of supply voltages Applications COND 200: Use for plating tank, rinse water, boiler and cooling tower, feed water and blowdown control, font solution make-up and control for printing, photographic developing, chemical production process, ion exchange systems, R.O. systems, industrial process water, wastewater, dilute acids, salts and bases.

Thermo Scientific Alpha TDS 200 Total Dissolved Solids Controller/Transmitter

Product Features Measure from pure water to electroplating rinse tank water with Thermo Scientific’s Alpha TDS 200. Reliable with straightforward process control, these control/transmitters measures with up to ±1 % full scale accuracy across eight conductivity/TDS ranges. For heightened security, use the Alpha TDS 200 with two levels of password security to protect calibration and meter settings from unauthorised tampering. ::Measures up to eight ranges at ±1 % full range accuracy ::Easy push-button calibration. Controller freezes data transmission and relay activities during calibration and maintenance ::Selectable temperature coefficient for higher TDS accuracy ::Two SPDT relays allows high/low set-points limit control. Each relay comes with their independent hysteresis to prevent relay-chattering ::Choice of automatic or manual temperature compensation. Three-wire system compensates error due to cable resistance ::Full-scale 4 to 20 mA galvanically isolated current output for process control ::85 to 250 VAC. 50/60 Hz or DC variable input allows controller to be used with a wide range of supply voltages Applications TDS 200: Ideal for drinking water, monitoring and control, hydroponics and aquaponic solution balance and control, pools and spa hardness and salinity control.

Thermo Scientific Alpha pH 500 pH/ORP 2-Wire Transmitter

Product Features Clear, uninterrupted data transmission is no problem with the Alpha pH 500, even in environments with electrical interferences. User-friendly and cost efficient, the transmitter comes with a large LCD screen to double up as a monitor – very convenient for quick checks on-the-spot. ::Measures, displays and transmit pH/ORP with temperature simultaneously ::Symmetrical Mode option, two-wire design and input-to-output isolation give clear, uninterrupted data transmission in electrically noisy ambient ::High quality, high resolution output at chart printers and other secondary devices ::Offset Adjustment Function allows you to adjust readings conveniently without having to remove electrode from the measurement tank or pipe ::Reliable, accurate measurements at different temperature with Automatic Temperature Compensation

Thermo Scientific Alpha COND 500 Conductivity 2-Wire Transmitter

Product Features The Alpha COND 500 transmits clear, uninterrupted conductivity readings simultaneously with temperature across six conductivity ranges. User-friendly and cost efficient, the transmitter features advances self-diagnostic capabilities, low maintenance requirements, and comes with a large LCD screen to double up as a monitor. ::±1 % accuracy across six Conductivity ranges ::Push-button calibration – quick, easy, no hassle ::High quality, high resolution output at chart printers and other secondary devices ::Reliable, accurate measurements at different temperature with Automatic Temperature Compensation ::Offset Adjustment Function allows you to adjust readings conveniently without having to remove electrode from the measurement tank or pipe

Thermo Scientific Alpha DO 500 Dissolved Oxygen 2-Wire Transmitter

Product Features The Alpha DO 500 Transmitter transmits dissolved oxygen readings across a wide measurement range to the peripheral instrument of your choice, reliably and accurately. ::Measures dissolved oxygen (in mg/L, ppm and % saturation) simultaneously with temperature :: ±1.5 % full scale accuracy ::Quick, easy calibration using atmospheric air as calibration media for 100 % air saturation ::Push-button calibration – quick, easy, no hassle ::High quality, high resolution output at chart printers and other secondary devices ::Reliable, accurate measurements at different temperature with Automatic Temperature Compensation ::Offset Adjustment Function allows you to adjust readings conveniently without having to remove electrode from the measurement tank or pipe

Thermo Scientific Alpha pH 560 pH/ORP Controller

Product Features Alpha pH 560 limit control meter simplifies the task of controlling several processes with two set-point relays. Separately adjustable high and low hysteresis ensures chatter-free signals, preventing false alarms and unnecessary down-times. ::Separately adjustable High/Low hysteresis with user-adjustable time delay of up to 2000 seconds for minimal chattering and false alarm ::Two switching contacts as set-point relays ::Large UV Light protected LCD with backlight ::Symmetrical Mode option gives clear, accurate readings in electrically noisy ambient ::Push button operation for easy set-up programming and customization ::US and NIST auto buffer recognition for quick, easy calibration ::Reliable, accurate measurements at different temperature with Automatic Temperature Compensation

Thermo Scientific Alpha COND 560 Conductivity Controller

Product Features The Alpha COND 560 controller simplifies process control with separately adjustable high/low hysteresis, and two switching contacts that act as set-point relays. Advanced control feature allows user to set alarm delay of up to 2000 seconds, preventing false alarms and unnecessary down-times. ::±1 % accuracy across six Conductivity ranges ::Separately adjustable High/Low hysteresis with user-adjustable time delay of up to 2000 seconds for minimal chattering and false alarms ::User-selectable range, cell-constant and temperature coefficient to suit different application needs, including pure water measurements ::Two switching contacts as set-point relays ::Large UV Light protected LCD with backlight ::Push button operation for easy set-up programming and customization ::Reliable, accurate measurements at different temperature with Automatic Temperature Compensation

Thermo Scientific Alpha pH 550 pH/ORP Monitor

Product Features With a large, custom-size LCD screen, the Alpha pH 550 provides clear visuals even in dark ambients. Monitor automatically recognizes US and NIST buffers for easy calibration, and is flexibly designed for panel mounting or wall mounting. ::Measures and displays pH/ORP with temperature simultaneously ::Symmetrical Mode option gives clear, accurate readings in electrically noisy ambient ::Push button operation for easy set-up programming and customization ::US and NIST auto buffer recognition for quick, easy calibration ::Reliable, accurate measurements at different temperature with Automatic Temperature Compensation

Thermo Scientific Alpha COND 550 Conductivity Monitor

Product Features Featuring quick, easy calibration with push-button off-set adjustment, the no-frills Alpha COND 550 offers user-friendly operations and reliable conductivity measurements at an excellent price point. Monitor comes with a large LCD screen for clear visuals in dark environments, and is flexibly designed for both panel mounting and wall mounting. ::±1 % accuracy across six conductivity ranges ::User-selectable range, cell-constant and temperature coefficient to suit different application needs, including pure water measurements ::Push button operation for easy set-up programming and customization ::Reliable, accurate measurements at different temperature with Automatic Temperature Compensation