Renk Ölçüm CIhazi
Konica Minolta Spectrophotometer Portable-CM-2500c
Specifications
Principal Specifications CM-2500c
Model |
Spectrophotometer CM-2500c |
Illumination/viewing system |
45°a:0° method (45° annular illumination, 0° vertical viewing) |
Light-receiving element |
Silicon photodiode array (dual 40 elements) |
Spectral separation device |
Diffraction grating |
Wavelength range |
360 nm to 740 nm |
Wavelength pitch |
10 nm |
Half bandwidth |
Approx. 10 nm |
Reflectance range |
0 to 175%, resolution: 0.01% |
Light source |
2 pulsed xenon lamps |
Measurement time |
Approx. 1.5 seconds |
Minimum interval between measurements |
4 seconds |
Battery performance |
Alkaline manganese: Approx. 1000 measurements, (at 23°C) |
Measurement/illumination area |
Ø 7 mm / Ø 11 mm |
Repeatability |
Colorimetric Value: Standard deviation within ΔE*ab 0.05 (Measurement conditions: White calibration plate measured 30 times at 10-second intervals after white calibration was performed) |
Inter instrument agreement |
Within ΔE*ab 0.25 (Average for 12 BCRA Series II color tiles compared to values measured with master body; at 23°C) |
Measurement mode |
Single measurement/automatic averaging of multiple measurements (auto mode: 3, 5, 8 times/manual mode) |
Interface |
RS-232C standard |
Observer condition |
CIE: 2° and 10° standard observer |
Illuminant condition |
CIE: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) |
Display data |
Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result, ASSESSMENTS (Except for Japanese mode) |
Color space/colorimetric data |
L*a*b*, L*C*h, CMC(1:1), CMC(2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ, MI, WI (ASTM E313), WI (CIE), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density status A/T, WI/Tint (CIE), CIE 00 |
Data memory |
700 |
Pass/Fail judgment |
Tolerance for color difference (Both box and elliptical tolerances can be set) |
Power source |
4 AA-size batteries or AC adapter |
Dimensions (W × H × D) |
69 × 96 × 193 mm |
Weight |
Approx. 670 g (without batteries) |
Operating temperature/humidity range |
5 - 40°C, relative humidity 80% or less (at 35°C) with no condensation |
Storage temperature/humidity range |
0 - 45°C, relative humidity 80% or less (at 35°C) with no condensation |
Standard accessories |
White calibration plate, RS-232C cable, AC adapter, AA-size battery (×4) |
Optional Accessories |
Hard case, Dust cover set, Dust cover, SpectraMagic™NX (software), Zero calibration box. |