Measuring method Triangulation by light sectioning method Light source Semiconductor laser, Wavelength: 660 nm Laser class Class 2 (IEC 60825-1 Edition 2) Number of pixels taken 1.31 megapixels (1280 × 1024) Measurement distance 450 to 800 mm Receiving lens TELE, WIDE Measurement range (Units: mm) Distance TELE 450 mm TELE 800 mm WIDE 450 mm WIDE 800 mm     Direction X × Y 79 × 99 141 × 176 150 × 188 267 × 334     Z 54 97 109 194     XY direction measurement interval (Units: mm) 0.08 0.14 0.16 0.28     Accuracy (Distance between balls)*1 ±40 µm Precision (Z, σ)*2 4 µm Auto-focus Provided Auto-exposure Provided Scan time Approx. 2 sec. or more (1 scan) Preview function Approx. 0.4 sec./scan Scanning ambient lighting condition 500 lx or less Output interface USB 2.0 High Speed Power Included AC Adapter Input voltage: 100 to 240 VAC (50/60 Hz) Rating: 1.4 A (at 100 VAC input) Dimensions 295 (W) × 190 (H) × 200 (D) mm (Excluding grips and lens) Weight Approx. 6.7 kg Operating temperature/humidity range 10 to 40 °C; Relative humidity 65% or less (no condensation) Storage temperature/humidity range -10 to 40°C; Relative humidity 85% or less (at 35°C, no condensation) PDF Dosyasını İndir

Konica Minolta Non Contact 3D Digitizer -VI-9i

Principal Specifications Type Non-contact 3D digitizer Measuring Method Triangulation light block method Light-Receiving Lenses (Interchangeable) TELE Focal distance f=25 mm MIDDLE Focal distance f=14 mm WIDE Focal distance f=8 mm Scan Range 0.6 to 1.0 m (In Standard mode) 0.5 to 2.5 m (In Extended mode) Laser Scan Method Galvanometer-driven rotating mirror Laser Class Class 2 (IEC60825-1), Class 1 (FDA) X Direction Input Range (In Extended mode) TELE 93 to 463 mm MIDDLE 165 to 823 mm WIDE 299 to 1495 mm Y Direction Input Range (In Extended mode) TELE 69 to 347 mm MIDDLE 124 to 618 mm WIDE 224 to 1121 mm Z Direction Input Range (In Extended mode) TELE 26 to 680 mm MIDDLE 42 to 1100 mm WIDE 66 to 1750 mm Accuracy (X,Y,Z) ±0.05 mm (Using TELE lens at distance of 0.6 m, with Field Calibration System, Konica Minolta's standard, at 20°C) Precision (Z, σ ) 0.008 mm (Using TELE lens at distance of 0.6 m, Konica Minolta's standard, at 20°C) Input Time (per scan) 2.5 sec Transfer Time to Host Computer Approx. 1.5 sec Ambient Lighting Condition Office environment, 500 lx or less Imaging Element 3D data: 1/3-inch frame transfer CCD (340,000 pixels) Color data: Common with 3D data (color separation by rotary filter) Number of Output Pixels 3D data/Color data: 640 x 460 Output Format 3D data: Konica Minolta format, & (STL,DXF, OBJ, ASCII points, VRML) (Converted to 3D data by the Polygon Editing Software/ standard accessory) Color data: RGB 24-bit raster scan data Data File Size Total 3D and color data capacity: 3.6MB per data Viewfinder 5.7-inch LCD (320 × 240 pixels) Output Interface SCSI II (DMA synchronous transfer) Power Commercial AC power, 100 to 240 V (50/60Hz), rated current 0.6 A (at 100 VAC) Dimensions 221 (W) × 412 (H) × 282 (D) mm Weight Approx. 15 kg (with lens attached) Operating temperature/humidity range 10°C to 40°C, relative humidity 65% or less with no condensation Storage temperature/humidity range 0°C to 40°C, relative humidity 85% or less (at 35°C) with no condensation Regulatory approvals UL 61010A-1, CSA-C22.2 No.1010-1, etc.   PDF Dosyasını İndir

Konica Minolta Non Contact 3D Digitizer -VIVID 910

Principal Specifications Model Non-contact 3D digitizer VI-910 Measurement method Triangulation light block method Autofocus Image surface AF (contrast method); active AF Light-receiving lenses (Exchangeable) TELE: Focal distance f=25mm MIDDLE: Focal distance f=14mm WIDE: Focal distance f=8mm Scan range (depth of field) 0.6 to 2.5m (2m for WIDE lens) Optimal 3D measurement range 0.6 to 1.2m Laser class Class 2 (IEC60825-1), Class 1 (FDA) Laser scan method Galvanometer-driven rotating mirror X-direction input range (varies with distance) 111 to 463mm (TELE), 198 to 823mm (MIDDLE), 359 to 1196mm (WIDE) Y-direction input range (varies with distance) 83 to 347mm (TELE), 148 to 618mm (MIDDLE), 269 to 897mm (WIDE) Z-direction input range (varies with distance) 40 to 500mm (TELE), 70 to 800mm (MIDDLE), 110 to 750mm (WIDE/FINE mode) Accuracy X: ±0.22mm, Y: ±0.16mm, Z: ±0.10mm to the Z reference plane (Conditions: TELE/FINE mode, Konica Minolta's standard) Input Time 0.3s (FAST mode), 2.5s (FINE mode), 0.5s (COLOR) Transfer time to host computer Approximately 1s (FAST mode) or 1.5s (FINE mode) Ambient lighting condition 500 lx or less Imaging element 3D data: 1/3 inch frame-transfer CCD (340,000 pixels) Color data: 3D data is shared (color separation by rotary filter) Number of output pixels 3D data: 307,000 (FINE mode), 76,800 (FAST mode) Color data: 640 × 480 × 24 bits color depth Output format 3D data: Konica Minolta format (& STL, DXF, OBJ, ASCII points, VRML; converted into 3D data by Polygon Editing Software provided as a standard accessory) Color data: RGB, 24-bit raster scan data Recording medium Compact flash memory card (128MB) Data file size Total 3D data and color data capacity: 1.6MB (FAST mode) per data, 3.6MB (FINE mode) per data Viewfinder 5.7-inch LCD (320 × 240 pixels) Output interface SCSI II (DMA synchronous transfer) Power Commercial AC power 100V to 240V (50 or 60Hz), rated current 0.6A (at 100V) Dimensions (W × H × D) 213 × 413 × 271mm (8-3/8 × 16-1/4 × 10-11/16 in.) Weight Approx. 11kg (25 lbs.) Operating temperature/humidity range 10 to 40°C, relative humidity 65% or less with no condensation Storage temperature/humidity range -10 to 50°C, relative humidity 85% or less (at 35°C) with no condensation   PDF Dosyasını İndir