KONICA MINOLTA

Renk Analiz Cihazi

Konica Minolta Pulse Oximeter-Pulsox-300 & Pulsox-300i

Specifications Principal Specifications CA-2000 Lens Standard lens Wide lens Telephoto lens* Light receptor 2/3-inch CCD image sensor (monochrome); Effective number of pixels: 1000×1000 (Measurement points: 980×980); Equipped with XYZ filter (closely matches CIE 1931 color-matching functions) and ND filter Typical measurement sizes/distances (Approx. length per side of square/distance) 98 mm/250 mm 145 mm/200 mm 115 mm/900 mm 210 mm/500 mm 410 mm/500 mm 275 mm/2000 mm 440 mm/1000 mm 850 mm/1000 mm 420 mm/3000 mm 890 mm/2000 mm 1770 mm/2000 mm With low-magnification macro ring: 57 mm/500 mm With high-magnification macro ring: 27 mm/300 mm Measurement luminance range (including when ND filter is used) 0.1 to 100,000 cd/m² 0.5 to 100,000 cd/m²(1 to 100,000 cd/m² when high-magnification macro ring is used) Size Body only 160 (W)×164 (H)×199 (D) mm (Height including handle: 211 mm) With lens/lens hood attached 224 (D) mm 219 (D) mm 224 (D) mm With low-magnification macro ring: 230 (D) mm With high-magnification macro ring: 237 (D) mm Weight Approx. 3.5 kg (when Standard lens and lens hood are attached) Power source Included AC adapter: 100 to 240V AC, 50/60Hz   PDF Dosyasını İndir

Konica Minolta CRT Color Analyzer-CA-100Plus

Specifications Principal Specifications CA-100Plus   CA-100Plus (Measuring Probe) CA-100Plus (High Luminance Measuring Probe) Detector Silicon photocell Silicon photocell Measurement diameter Ø 21 mm Ø 21 mm Display range Luminance 0.01 to 1000 cd/m2 0.01 to 2000cd/m2 Chromaticity Displayed in 4- or 3-digit values (selectable) Displayed in 4- or 3-digit values (selectable) Luminance Measurement range 0.05 to 1000 cd/m2 0.05 to 2000 cd/m2 Accuracy (for white)*1 ±2%, ±1 digit of reading (Temperature: 23°C±2°C, Relative humidity: (40±10)%) ±2%, ±1 digit of reading (Temperature: 23°C±2°C, Relative humidity: (40±10)%) Repeatability*1 0.05 to 1000 cd/m2 0.2%+1 digit (2σ) 0.05 to 2000 cd/m2 0.2%+1 digit (2σ) Chromaticity Measurement range 0.05 to 1000 cd/m2 0.05 to 2000 cd/m2 Accuracy*1 0.05 to 0.19 cd/m2 ±0.006 for white; 0.20 to 0.49 cd/m2 ±0.004 for white; 0.50 to 1000 cd/m2 ±0.003 for white; 40.00 cd/m2 ±0.002 for white, ±0.004 for monochrome*2 0.05 to 0.09 cd/m2 ±0.008 for white; 0.1 to 0.39 cd/m2 ±0.006 for white; 0.40 to 0.99 cd/m2 ±0.004 for white; 1.00 to 2000 cd/m2 ±0.003 for white; 40.00 cd/m2 ±0.002 for white, ±0.004 for monochrome*2 Repeatability*1 0.05 to 0.19 cd/m2 0.006 (2σ); 0.20 to 0.49 cd/m2 0.002 (2σ); 0.50 to 1000 cd/m2 0.001 (2σ) 0.05 to 0.09 cd/m2 0.009 (2σ); 0.1 to 0.39 cd/m2 0.006 (2σ); 0.40 to 0.99 cd/m2 0.002 (2σ); 1.00 to 2000 cd/m2 0.001(2σ) Measurement speed*3 xyLv 0.05 to 0.99 cd/m2 5 (4.5) meas./sec.*4 ; 1.00 to 1000 cd/m2 20 (17) meas./sec.*4 0.05 to 1.99 cd/m2 5 (4.5) meas./sec.*4 ; 2 to 2000 cd/m2 20 (17) meas./sec.*4 Display Digital xyLv, TΔuvLv, RGB, XYZ, u'v'Lv xyLv, TΔuvLv, RGB, XYZ, u'v'Lv Analog Δ x, Δ y, Δ Lv, R/G, B/G, Δ G, Δ R, B/R, G/R SYNC mode NTSC, PAL, EXT, UNIV, INT NTSC, PAL, EXT, UNIV, INT Object under measurement Vertical synchronous frequency: 40 to 200Hz Vertical synchronous frequency: 40 to 200Hz Memory channels 100 100 Analyzer function Standard function Standard function Interface USB (Version 1.1) or RS-232C (38,400bps or below) USB (Version 1.1) or RS-232C (38,400bps or below) Multi-point measurement Max. 5 points (Use 4-Probe Expansion Board CA-B04.) Max. 5 points (Use 4-Probe Expansion Board CA-B04.) Operating temperature/humidity range Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation Luminance change: ±2% ±1 digit of reading for white Chromaticity change: ±0.002 for white, 0.006 for monochrome (from reading of Konica Minolta's standard CRT*1, 40.00cd/m2, at 23°C, 40% Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation Luminance change: ±2% ±1 digit of reading for white Chromaticity change: ±0.002 for white, 0.006 for monochrome (from reading of Konica Minolta's standard CRT*1, 40.00cd/m2, at 23°C, 40% Storage temperature/humidity range 0 to 28°C: Relative humidity 70% or less with no condensation 28 to 40°C: Relative humidity 40% or less with no condensation 0 to 28°C: Relative humidity 70% or less with no condensation 28 to 40°C: Relative humidity 40% or less with no condensation Input voltage range 100 to 240V~, 50 to 60Hz, 50VA 100 to 240V~, 50 to 60Hz, 50VA Dimensions (W × H × D) Main unit, Probe 340 × 127 × 216 mm, Ø 45 × 142 mm 340 × 127 × 216 mm, Ø 45 × 142 mm Weight Main unit, Probe 3.58 kg, 285 g 3.58 kg, 285 g   PDF Dosyasını İndir

Konica Minolta Display Color Analyzer-CA-210

Specifications Principal Specifications CA-210 Receptor Silicon photocell Measurement area Ø 27mm Acceptance angle ±2.5°; Pointing function: By LED Measurement distance 30±10 mm Display range Luminance 0.01 to 1000 cd/m2 Chromaticity Displayed in 4- or 3-digit value (selectable) Luminance Measurement range 0.10 to 1000 cd/m2 Accuracy (for white) *1 ±2%, ±1 digit of reading (Temperature: 23°C ±2°C; Relative humidity:(40±10)%) Repeatability (2σ) *1 0.10 to 0.99 cd/m2: 0.2%+1digit; 1.0 to 1000 cd/m2: 0.1%+1digit Chromaticity Measurement range 0.10 to 1000 cd/m2 Accuracy *1 0.10 to 4.99 cd/m2: ±0.008 for white 5.00 to 39.99 cd/m2: ±0.005 for white 40.00 to 1000 cd/m2: ±0.003 for white 160 cd/m2: ±0.002 for white; ± 0.004 for monochrome *2 Repeatability (2σ) *1 0.10 to 0.19 cd/m2: 0.015 0.20 to 0.49 cd/m2: 0.008 0.50 to 1.99 cd/m2: 0.003 2.00 to 1000 cd/m2: 0.001 Measurement speed (meas./sec.) xyLv*3 0.10 to 1.99 cd/m2: 5 (4.5) 4 cd/m2 or greater: 20 (17) Display Digital xyLv, XYZ, TΔuvLv, u'v'Lv, RGB analyze Analog ΔxΔyΔLv, R/G B/G ΔG, ΔR B/R G/R LCD 16 characters × 2 lines (with backlight) SYNC mode NTSC, PAL, EXT, UNIV, INT Measurement subject Vertical synchronous frequency: 40 to 200Hz Memory channels 100 Analyzer function Standard function Interface USB (Rev. 1.1) or RS-232c (38,400 bps maximum) Multi-point measurement Max. 5 points (using optional 4-Probe Expansion Board CA-B14) Software Solutions SDK software (supplied as standard accessory) Operating temperature/humidity range Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation. Luminance change: ±2% ±1 digit of reading for white; Chromaticity change: ±0.002 for white, ±0.006 for monochrome from reading of Konica Minolta's standard LCD *1, 160.0 cd/m2 at 23°C 40%RH Storage temperature/humidity range 0 to 28°C: Relative humidity 70% or less with no condensation; 28 to 40°C: Relative humidity 40% or less with no condensation Input voltage range 100 to 240V~50/60Hz, 50VA Dimensions (W × H × D) Main body: 340 × 127 × 216 mm Probe: Ø 49 × 204 mm Weight Main body: 3.58 kg; Probe: 520 g   PDF Dosyasını İndir

Konica Minolta Luminance & Color Meter-CS-100A

Specifications Principal Specifications CS-100A Type SLR spot colorimeter for measuring light-source and surface luminance and chromaticity Acceptance angle 1° Optical system 85 mm f/2.8 lens; SLR viewing system; flare factor less than 1.5% Angle of view 9° with 1° measurement area indication Focusing distance 1014 mm (40 in.) to infinity Receptors 3 silicon photocells filtered to detect primary stimulus values for red, green, and blue light Spectral response Closely matches CIE 1931 Standard Observer curves Response time FAST: Sampling time: 0.1s, Time to display: 0.8 to 1.0s; SLOW: Sampling time: 0.4s, Time to display: 1.4 to 1.6s Luminance units: cd/m2 or fL (switchable) Measuring range FAST: 0.01 to 299,000 cd/m2 (0.01 to 87,530fL); SLOW: 0.01 to 49,900 cd/m2 (0.01 to 14,500fL) Accuracy Luminance (Y): ±2% of reading ±1 digit Chromaticity (x,y): ±0.004 (Illuminant A measured at ambient temperature of 18 to 28°C/64 to 82°F) Repeatability Luminance (Y): ±0.2% of reading ±1 digit Chromaticity (x,y): FAST: Y 100 cd/m2 or above: ±0.001; 48.1 to 99.9 cd/m2: ±0.002; Below 48.1 cd/m2: Below measurement range SLOW: Y 25.0 cd/m2 or above: ±0.001; 12.0 to 24.9 cd/m2: ±0.002; Below 12.0 cd/m2: Below measurement range (Measurement subject: Illuminant A) Target value 1; set by measurement or numerical input Measurement modes Absolute color: Yxy; Color difference: Δ(Yxy) Display External: LCD; 3 values (Y, x, and y) of 3 digits each with additional indications Viewfinder: 3-digit LCD (showing luminance value y ) with LED backlight Data communication RS-232C; baud rate: 4800bps External control Measurement process can be started by external device connected to data output terminal Power source One 9V battery; Power can also be supplied via data output terminal Operating temperature/humidity range 0 to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation Dimensions (W × H × D) 79 × 208 × 154 mm (3-1/8 × 8-3/16 × 6-1/16 in.) Weight 890 g (2 lb.) without battery Standard accessories Lens cap; Eyepiece cap; Protective filter; ND eyepiece filter; 9V battery; Chromaticity chart; Case  

Konica Minolta Luminance & Color Meter-CS-200

Specifications Principal Specifications CS-200 Model CS-200 Measurement range 0.01 - 200,000 cd/m2 (Measuring angle 1°) 0.01 - 5,000,000 cd/m2 (Measuring angle 0.2°) 0.01 - 20,000,000 cd/m2 (Measuring angle 0.1°) Accuracy (Measuring angle 1°) #1 (Temperature: 23°C±2°C, Relative humidity: 65% max.) 150 cd/m2 ( for Illuminant A ) : Lv ±2 % ±1digit ; xy ±0.002 0.01-0.5 cd/m2 ( for Illuminant A ) : Lv ±0.02 cd/m2 ±1digit ; 0.5-1 cd/m2 ( for Illuminant A ) : Lv ±0.02 cd/m2 ±1digit ; xy ±0.007 1-10 cd/m2 ( for Illuminant A ) : Lv ±2 % ±1digit ; xy ±0.004 10-200,000 cd/m2 ( for Illuminant A) : Lv ±2 % ±1digit ; xy ±0.003 5000 cd/m2 ( for Illuminant A ) : color filter (R, G, B) ; xy ±0.006 Repeatability (Measuring angle 1°) #2 0.01-1 cd/m2 ( for Illuminant A ) : Lv ±0.01 cd/m2 ±1digit ;(2σ/AUTO) 1-2 cd/m2 ( for Illuminant A ) : Lv ±0.5 % ±1digit ; xy 0.002 (2σ/AUTO) 2-4 cd/m2 ( for Illuminant A ) : Lv ±0.5 % ±1digit ; xy 0.001 (2σ/AUTO) 4-8 cd/m2 ( for Illuminant A ) : Lv ±0.5 % ±1digit ; xy 0.0005 (2σ/AUTO) 8-200,000 cd/m2 ( for Illuminant A ) : Lv ±0.1% ±1digit ; xy 0.0004 (2σ/AUTO) Measurement time Automatic setting between 1s and 60s (AUTO); Automatic setting to 1s or 3s (LTD. AUTO) 0.5 sec / meas. (Super-FAST) 1 sec / meas.(FAST) 3 sec / meas. (SLOW) 12 sec / meas. (Super-SLOW) Measurement method Spectral method, Grating + linear photo diode array Measuring angle 1°, 0.2°, 0.1°(switchable) Minimum measuring area 0.5 mm 0.1 mm (close up lens) Minimum measuring distance 296 mm (Distance from front edge of metal lens barrel) Observer 2/10 degrees Color space Lv x y, Lv u' v', Lv TΔuv, XYZ, dominant wavelength Measurement synchronization setting range Vertical synchronization frequency : 40.00 to 200.00Hz Interface USB 1.1 Power source AC adapter or 4 AA-Size Batteries Battery life Approx. 3 hours (continuous measurement / Fast mode / AA-size alkaline cells) Size 95 mm (W) × 127 mm (H) × 330 mm (L) Weight 1.8 kg (without battery) Operating temperature/humidity range 0°C to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature /humidity range 0°Cto 45°C,relative humidity 85% or less (at 35°C)with no condensation  

Konica Minolta Spectroradiometer-CS-2000

Specifications Principal Specifications CS-2000 Model CS-2000 Wavelength range 380 to 780 nm Wavelength resolution 0.9 nm/pixel Display wavelength bandwidth 1.0 nm Wavelength precision ±0.3 nm (median wavelength: 435.8 nm, 546.1 nm, 643.8 nm Hg-Cd lamp) Spectral bandwidth 5 nm or less (half bandwidth) Measuring angle (selectable) 1° 0.2° 0.1° Measurement luminance range (Illuminant A) 0.003 to 5,000 cd/m2 0.075 to 125,000 cd/m2 0.3 to 500,000 cd/m2 Minimum luminance display 0.00002 cd/m2 Accuracy: Luminance (Illuminant A) *1 ±2% Accuracy: Chromaticity (Illuminant A)*1 x,y :±0.003 (0.003 to 0.005 cd/m2) x,y :±0.002 (0.005 to 0.05 cd/m2) x :±0.0015 (0.05 cd/m2 to) y :±0.001 x,y :±0.003 (0.075 to 0.125 cd/m2) x,y :±0.002 (0.125 to 1.25 cd/m2) x :±0.0015 (1.25 cd/m2 to ) y :±0.001 x,y :±0.003 (0.3 to 0.5 cd/m2) x,y :±0.002 (0.5 to 5 cd/m2) x :±0.0015 (5 cd/m2 to ) y :±0.001 Repeatability: Luminance(2σ) 0.4 % (0.003 to 0.05 cd/m2) 0.3 % (0.05 to 0.1 cd/m2) 0.15 % (0.1 to 5,000 cd/m2) 0.4 % (0.075 to 1.25 cd/m2) 0.3 % (1.25 to 2.5 cd/m2) 0.15 % (2.5 to 125,000 cd/m2) 0.4 % (0.3 to 5 cd/m2) 0.3 % (5 to 10 cd/m2) 0.15 % (10 to 500,000 cd/m2) Repeatability: Chromaticity(2σ) 0.002 (0.003 to 0.005 cd/m2) 0.001 (0.005 to 0.1 cd/m2) 0.0006 (0.1 to 0.2 cd/m2) 0.0004 (0.2 to 5,000 cd/m2) 0.002 (0.075 to 0.125 cd/m2) 0.001 (0.125 to 2.5 cd/m2) 0.0006 (2.5 to 5 cd/m2) 0.0004 (5 to 125,000 cd/m2) 0.002 (0.3 to 0.5 cd/m2) 0.001 (0.5 to 10 cd/m2) 0.0006 (10 to 20 cd/m2) 0.0004 (20 to 500,000 cd/m2) Polarization error 1°: 2% or less (400 to 780 nm); 0.1° and 0.2°: 3% or less (400 to 780 nm) Integration time Fast: 0.005 to 16 sec; Normal: 0.005 to 120 sec. Measurement time 2 sec min. (Manual mode) to 243 sec. max. (Normal mode) Color space mode LVxy, Lvu'v', LvTΔuv, XYZ, dominant wavelength, spectral graph Interface USB 1.1 Operating temperature/humidity range 5 to 35°C, relative humidity 80% or less with no condensation Storage temperature/humidity range 0 to 45°C, relative humidity 80% or less with no condensation Size Main unit: 158 (W) × 200 (H) × 300 (D) mm; Lens: Φ70 × 95 mm Weight 6.2 kg   PDF Dosyasını İndir

Konica Minolta Spectroradiometer-CS-2000A

Specifications Principal Specifications CS-2000A Model CS-2000A Measurement angle 0.1°, 0.2°, 1° selectable Measurement wavelength range 380 to 780nm Wavelenght resolution 0.9nm/pixel Display wavelength pitch 1.0nm Median wavelength precision ±0.3nm (at 435.8nm, 546.1nm, and 643.8nm) Half bandwidth 5nm or less Luminance measurment range (for Standard illuminant A) 0.1° measurement angle: 0.05 to 500,000 cd/m2 0.2° measurement angle: 0.0125 to 125,000 cd/m2 1° measurement angle: 0.0005 to 5,000 cd/m2 Accuracy Luminance ±2%   Chromaticity (1° measurement angle) x,y: ±0.002 (0.001 to 0.05 cd/m2) x,y: ±0.0015 (from 0.05 cd/m2)   Repeatability Luminance (1°C measurement angle) 1.5% (0.0005 to 0.001 cd/m2) 0.7% (0.001 to 0.003 cd/m2) 0.25% (0.003 to 0.05 cd/m2) 0.15% (0.05 to 5,000 cd/m2)   Chromaticity (1° measurement angle) x: 0.003 y: 0.0035 (0.001 to 0.003 cd/m2) x: 0.001 y: 0.0015 (0.003 to 0.1 cd/m2) x: 0.0006 y: 0.0006 (0.1 to 0.2 cd/m2) x: 0.0004 y: 0.0004 (0.2 to 5,000 cd/m2)   Polarization error 0.1°, 0.2° measurement angle: 3% or less 1° measurement angle: 2% or less Measurement time Approx. 2 to 243 sec. Color space mode Lv x y, Lv u’ v’, Lv TΔuv, XYZ ,spectral waveform, dominant wavelength, excitation purity scotopic luminosity (with CS-S10w Professional) Interface USB 1.1 Operating temperature/humidity range 5 to 30°C; Relative humidity 80% or less with no condensation Power supply AC adapter (100 to 240V~, 50/60 Hz) Dimensions (W × H × D) 158 × 200 × 300mm (Main unit) Ø70 × 95mm (Lens) Weight 6.2kg (including lens)   PDF Dosyasını İndir