Işık Ölçüm Cihazi
Konica Minolta Illuminance Meter-T-10
Specifications
Principal Specifications T-10 Series
Model |
Illuminance meter T-10 |
Illuminance meterT-10M |
Type |
Multi-function digital illuminance meter with detachable receptor head |
|
Receptor |
Silicon photocell |
|
Relative Spectral Response* |
Within 6% (f1´) of the CIE spectral luminous efficiency V (λ) |
|
Cosine Correction Characteristics |
Within ±1% at 10° ; Within ±2% at 30° ; Within ±6% at 50° ; Within ±7% at 60° ; Within ±25% at 80° |
|
Illuminance units |
Lux (lx) or foot candles (fcd) (switchable) |
|
Measuring range |
Auto range (manual 5 range at the time of analog output) |
|
Measuring function |
Illuminance(lx). illuminance difference(lx). illuminance ratio(%). integrated illuminance(lx·h). integration time(h). average illuminance(lx). |
|
Measuring range |
Illuminance 0.01 to 299,900 lx 0.001 to 29,990 fcd |
|
Integrated illuminance 0.01 to 999,900 × 103 lx·h 0.001 to 99,990 × 103 fcd·h / 0.001 to 9999 h |
||
User calibration function |
CCF(Color Correction Factor) setting function |
|
Accuracy |
±2% ±1digit of displayed value (based on Konica Minolta standard) |
|
Temperature/humidity drift |
Within ±3% ±1digit (of value displayed at 20°C/68°F ) within operating temperature/humidity range |
|
Digital output |
RS-232C |
|
Analog output |
1mV/digit,3V at maximum reading; Output impedance: 10KΩ; 90% response time: FAST setting: 1ms, SLOW setting: 1s |
|
Display |
3 or 4 Significant-digit LCD with back-light illumination |
|
Operating temperature |
-10 to 40°C, relative humidity 85% or less (at 35°C) with no condensation |
|
Storage temperature |
-20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation |
|
Power source |
2 AA-size batteries / AC adapter (optional) |
|
Battery life |
72 hours or longer (when alkaline batteries are used) in continuous measurement |
|
Dimensions |
69 × 174 × 35 mm (2-6/16×6-14/16×1-7/16 in.) |
Main body : 69 × 161.5 ×30 mm (2-6/16×6-6/16×1-3/16 in.) |
Weight |
200 g (7.0 oz.) without battery |
205 g (7.2 oz.) without battery |
Standard accessories |
Ø 3.5 mm (Ø 1/8 in.) subminiature plug for analog output ; |
Ø 3.5 mm (Ø 1/8 in.) subminiature plug for analog output ; |
Optional accessories |
Receptor head ; Adapter for Multi-point ; AC Adapter ; Data processing software |
Etiketler : Ankyralab KONICA MINOLTA Işık Ölçüm Cihazi Konica Minolta Illuminance Meter-T-10, Laboratory Devices, Laboratory Equipments, Laboratory Tools, Ankyra Laboratory Tools, Ankyralab Laboratory Devices, Ankyralab Laboratory Systems