Principal Specifications CA-100Plus
|
CA-100Plus (Measuring Probe) |
CA-100Plus (High Luminance Measuring Probe) |
|
Detector |
Silicon photocell |
Silicon photocell |
|
Measurement diameter |
Ø 21 mm |
Ø 21 mm |
|
Display range |
Luminance |
0.01 to 1000 cd/m2 |
0.01 to 2000cd/m2 |
Chromaticity |
Displayed in 4- or 3-digit values (selectable) |
Displayed in 4- or 3-digit values (selectable) |
|
Luminance |
Measurement range |
0.05 to 1000 cd/m2 |
0.05 to 2000 cd/m2 |
Accuracy (for white)*1 |
±2%, ±1 digit of reading (Temperature: 23°C±2°C, Relative humidity: (40±10)%) |
±2%, ±1 digit of reading (Temperature: 23°C±2°C, Relative humidity: (40±10)%) |
|
Repeatability*1 |
0.05 to 1000 cd/m2 |
0.05 to 2000 cd/m2 |
|
Chromaticity |
Measurement range |
0.05 to 1000 cd/m2 |
0.05 to 2000 cd/m2 |
Accuracy*1 |
0.05 to 0.19 cd/m2 ±0.006 for white; 0.20 to 0.49 cd/m2 ±0.004 for white; 0.50 to 1000 cd/m2 ±0.003 for white; 40.00 cd/m2 ±0.002 for white, ±0.004 for monochrome*2 |
0.05 to 0.09 cd/m2 ±0.008 for white; 0.1 to 0.39 cd/m2 ±0.006 for white; 0.40 to 0.99 cd/m2 ±0.004 for white; 1.00 to 2000 cd/m2 ±0.003 for white; 40.00 cd/m2 ±0.002 for white, ±0.004 for monochrome*2 |
|
Repeatability*1 |
0.05 to 0.19 cd/m2 0.006 (2σ); 0.20 to 0.49 cd/m2 0.002 (2σ); 0.50 to 1000 cd/m2 0.001 (2σ) |
0.05 to 0.09 cd/m2 0.009 (2σ); 0.1 to 0.39 cd/m2 0.006 (2σ); 0.40 to 0.99 cd/m2 0.002 (2σ); 1.00 to 2000 cd/m2 0.001(2σ) |
|
Measurement speed*3 |
xyLv |
0.05 to 0.99 cd/m2 5 (4.5) meas./sec.*4 ; 1.00 to 1000 cd/m2 20 (17) meas./sec.*4 |
0.05 to 1.99 cd/m2 5 (4.5) meas./sec.*4 ; 2 to 2000 cd/m2 20 (17) meas./sec.*4 |
Display |
Digital |
xyLv, TΔuvLv, RGB, XYZ, u'v'Lv |
xyLv, TΔuvLv, RGB, XYZ, u'v'Lv |
Analog |
Δ x, Δ y, Δ Lv, R/G, B/G, Δ G, Δ R, B/R, G/R |
||
SYNC mode |
NTSC, PAL, EXT, UNIV, INT |
NTSC, PAL, EXT, UNIV, INT |
|
Object under measurement |
Vertical synchronous frequency: 40 to 200Hz |
Vertical synchronous frequency: 40 to 200Hz |
|
Memory channels |
100 |
100 |
|
Analyzer function |
Standard function |
Standard function |
|
Interface |
USB (Version 1.1) or RS-232C (38,400bps or below) |
USB (Version 1.1) or RS-232C (38,400bps or below) |
|
Multi-point measurement |
Max. 5 points (Use 4-Probe Expansion Board CA-B04.) |
Max. 5 points (Use 4-Probe Expansion Board CA-B04.) |
|
Operating temperature/humidity range |
Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation Luminance change: ±2% ±1 digit of reading for white Chromaticity change: ±0.002 for white, 0.006 for monochrome (from reading of Konica Minolta's standard CRT*1, 40.00cd/m2, at 23°C, 40% |
Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation Luminance change: ±2% ±1 digit of reading for white Chromaticity change: ±0.002 for white, 0.006 for monochrome (from reading of Konica Minolta's standard CRT*1, 40.00cd/m2, at 23°C, 40% |
|
Storage temperature/humidity range |
0 to 28°C: Relative humidity 70% or less with no condensation 28 to 40°C: Relative humidity 40% or less with no condensation |
0 to 28°C: Relative humidity 70% or less with no condensation 28 to 40°C: Relative humidity 40% or less with no condensation |
|
Input voltage range |
100 to 240V~, 50 to 60Hz, 50VA |
100 to 240V~, 50 to 60Hz, 50VA |
|
Dimensions (W × H × D) |
Main unit, Probe |
340 × 127 × 216 mm, Ø 45 × 142 mm |
340 × 127 × 216 mm, Ø 45 × 142 mm |
Weight |
Main unit, Probe |
3.58 kg, 285 g |
3.58 kg, 285 g |